Problem solving guide
71
Water inlet fault
Problem
Cause and remedy
The buzzer is sounding.
One of the following
fault messages appears
in the display:
Water inlet fault
Please open the stopcock
The stopcock is closed.
Open the stopcock fully.
Water intake
Before rectifying the problem:
Switch the dishwasher off using the
sensor.
The water intake is restricted.
Open the stopcock fully and start the programme
again.
Clean the water inlet filter (see "Maintenance").
The water pressure at the intake is lower than 50
kPa (0.5 bar).
Seek professional advice.
The following message
appears in the display
during the
SolarSave
pro-
gramme:
Intake temp. too low
The intake water has not reached the required tem-
perature of 45 °C (see "Plumbing, Connection to the
water supply").
Start the programme again.
If the fault message appears again, select a differ-
ent programme.