Installation
*INSTALLATION*
94
A water supply with 3/8"
Compression
Connection
(thread connection of
9/16" – 24 UNEF) must be provided on
site. If this type of faucet is not avail-
able, only a qualified installer may con-
nect the dishwasher to the domestic
water supply.
A backflow preventer is not required.
The appliance meets the requirements
of the applicable DIN standards.
The water-connection pressure needs
to be between 7.25 and 145 psi (50 and
1,000 kPa). If the water-connection
pressure is too high, a pressure reduc-
ing valve must be installed.
Risk of damage from leaking wa-
ter.
The connection point is subject to
water pressure. Water leaking from it
can cause damage.
You should therefore open the faucet
slowly and check for leaks. Correct
the position of the seal and screw
thread if appropriate.
Risk of damage from leaking wa-
ter.
The intake hose is under water pres-
sure.
The intake hose must not be short-
ened or damaged in any way.
Risk of damage due to excessive
pressure.
A brief increase in the water pressure
can damage components of the
dishwasher.
This dishwasher must only be oper-
ated when it is connected to a fully
primed plumbing system.