Safety 

Precautions

 Page 4

• 

• 

• 

• 

• 

• 

• 
• 

• 

• 

• 

• 
• 

 CAUTION

• 

• 

• 

• 
• 

This appliance can be used by children aged from 8 years and above and person with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been 

given supervision or instruction concerning use of the appliance in a safe way and understand 

the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance 

shall not be made by children without supervision.  (be applicable for the European Countries)

This appliance is not intended for use by persons (including childern) with reduced physical, 

sensory or mental capabilities or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a person responsible for 

their safety.  Children should be supervised to ensure that they do not play with the appliance.

(be applicable for other countries except the European Countries )

If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or 

similarly qualified persons in order to avoid a hazard.

Prior to cleaning or other maintenance, the appliance must be disconnected from the supply 

mains.

Do not install the appliance in a location that may be exposed to combustible gas. If 

combustible gas accumulates around the unit, it may cause fire.

If the appliance is knocked over during use, turn off the unit and unplug it from the main power 

supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the 

unit has been damaged, contact a technician or customer service for assistance.

In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning. 

Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar 

coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area 

and where it will not be tripped over.

Do not operate unit with a damaged cord or plug. Discard unit or return to an authorized 

service facility for examination and/or repair. 

To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control 

device.

The appliance shall be installed in accordance with national wiring regulations.

Contact the authorised service technician for repair or maintenance of this unit. 

Turn off the product when not in use. 

 

The manufactures nameplate is located on the rear panel of the unit and contains electrical and other 

technical data specific to this unit.

Be sure the unit  is properly grounded. To minimize shock and fire hazards, proper grounding is 

important. The power cord is equipped with a three-prong grounding plug for protection against 

shock hazards.

Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to 

use is not adequately grounded or protected by a time delay fuse or circuit breaker(please refer to the

nameplate for the electrical data), have a qualified electrician install the proper receptacle.

Do not operate your air conditioner in a wet room such as a bathroom or laundry room. 
The unit s circuit board(PCB) is designed with a fuse to provide overcurrent protection. 

The

specifications of the fuse are printed on the circuit board, such as: 

T 3.15A/250V (or 350V), etc.

Summary of Contents for MDDF-16

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Page 2: ...ance Table of Contents Control Panel Features 12 Other features 15 Clean the grille and case 18 Clean the bucket 18 Troubleshooting Tips 19 Clean the air filter 18 When not using the unit for long tim...

Page 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Page 4: ...been damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut o to avoid damage to the machine due to lightning Do not run cord under carpeting Do not c...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Page 11: ...prior notice Preparation rear front rear front rear front control panel control panel shoes dryer cover shoes dryer pipe drain hose outlet drain hose outlet drain hose outlet power cord buckle power c...

Page 12: ...to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a...

Page 13: ...s Then press pad to operate the desired settings For panel H Indicator Function Indicator Function Timer ON light Timer OFF light Bucket full light Air purifier light Low fan speed light Med fan speed...

Page 14: ...fan control to Normal Note The turbo button is disabled in Dryer mode the Self clean Air purifier or Anti mould functions Pressing the turbo button for more than 3 seconds enables the Self clean funct...

Page 15: ...midity sensor error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service P2 Bucket is...

Page 16: ...on will also be cancelled There are two ways to remove collected water 1 Use the bucket When the unit is off if the bucket is full the unit will beep 8 times on some models and the Full Water indicato...

Page 17: ...the drain hose Select the desired humidity setting and fan speed on the unit for continuous draining to start 2 Continuous draining Note When the continuous drain feature is not being used remove the...

Page 18: ...urely seated for the dehumidifier to operate The air filter behind the front grille should be checked and cleaned at least every two weeks or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTE...

Page 19: ...upright as it should be The floor surface is not level Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The...

Page 20: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...