background image

When first using the dehumidifier, operate the unit

continuously 24 hours. Make sure the plastic cover on

the continuous drain hose outlet install stightly 

properly so there are no leaks.

This unit is designed to operate with a working 

environment between 5 C/41 F and 32 C/90 F,

 and between 30%(RH) and 80%(RH).

If the unit has been switched off and needs to be 

switched on again quickly , allow approximately three 

minutes for the correct operation to resume.

Do not connect the dehumidifier to a multiple socket

outlet, which is also being used for other electrical

  applications only. This dehumidifer should not be used

  for commercial or industrial applications.

  Place the dehumidifier on a smooth, level floor strong

  enough to support the unit with a full bucket of water.

  Allow at least 20cm of air space on all sides of the unit

  for good air circulation (at least 40cm of air space on 

  air outlet).

  Place the unit in an area where the temperature will 

  not fall below 5 C(41 F). The coils can become covered 

  with frost at temperatures below 5 C(41 F), which may 

  reduce performance. 

  Place the unit away from the clothes dryer, heater or 

  radiator.

  Use the unit to prevent moisture damage anywhere 

  books or valuables are stored.

  Use the dehumidifier in a basement to help prevent

  moisture damage. 

  The dehumidifier must be operated in an enclosed 

  area to be most effective.

  Close all doors, windows and other outside openings 

  to the room.

A dehumidifier operating in a basement will have little 

or no effect in drying an adjacent enclosed storage 

area, such as a closet, unless there is adequate 

circulation of air in and out of the area.

  Do not use outdoors.

  This dehumidifer is intended for indoor residential 

Casters(At four points on the bottom of unit)

   Casters can  move freely.

   Do not force casters to move over carpet, nor 

   move the unit with water in the bucket.

   (The unit may tip over and spill water.)

 Page 12 

Operating Instructions 

Positioning the unit

When using the unit

• 

• 

Control Panel Features

NOTE: The following control panels 

are for explanation purpose only.  The control panel of the unit you 

purchased may be slightly different according to the models. Your machine may not contain some indicators or 

buttons. The actual shape shall prevail.   

20cm or more

40cm or more

20cm or more

20cm or more

40cm or more

 

 

 
 

 

 

 

 

  
 

 

 

 

appliances.

Select a suitable location, making sure you have easy

access to an electrical outlet. 

Plug the unit into a  electrical socket-outlet with earth

connection.

Make sure the Water bucket is correctly fitted 

otherwise the unit will not operate properly. 

 

 

 

 

NOTE:When the water in the bucket reaches to a certain

level,please be careful to move the machine to avoid it

falling down.  

 Operating

Instructions

Summary of Contents for MDDF-16

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Page 2: ...ance Table of Contents Control Panel Features 12 Other features 15 Clean the grille and case 18 Clean the bucket 18 Troubleshooting Tips 19 Clean the air filter 18 When not using the unit for long tim...

Page 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Page 4: ...been damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut o to avoid damage to the machine due to lightning Do not run cord under carpeting Do not c...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Page 11: ...prior notice Preparation rear front rear front rear front control panel control panel shoes dryer cover shoes dryer pipe drain hose outlet drain hose outlet drain hose outlet power cord buckle power c...

Page 12: ...to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a...

Page 13: ...s Then press pad to operate the desired settings For panel H Indicator Function Indicator Function Timer ON light Timer OFF light Bucket full light Air purifier light Low fan speed light Med fan speed...

Page 14: ...fan control to Normal Note The turbo button is disabled in Dryer mode the Self clean Air purifier or Anti mould functions Pressing the turbo button for more than 3 seconds enables the Self clean funct...

Page 15: ...midity sensor error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service P2 Bucket is...

Page 16: ...on will also be cancelled There are two ways to remove collected water 1 Use the bucket When the unit is off if the bucket is full the unit will beep 8 times on some models and the Full Water indicato...

Page 17: ...the drain hose Select the desired humidity setting and fan speed on the unit for continuous draining to start 2 Continuous draining Note When the continuous drain feature is not being used remove the...

Page 18: ...urely seated for the dehumidifier to operate The air filter behind the front grille should be checked and cleaned at least every two weeks or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTE...

Page 19: ...upright as it should be The floor surface is not level Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The...

Page 20: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...

Reviews: