background image

Removing the collected water

     Auto Stop program is initiated. Press it again the 

     Timer On indicator light illuminates. It indicates the

     Auto Start is initiated.

·    When the unit is off, first press the Timer 

     button, the Timer On indicator light 

     illuminates. It indicates the Auto Start program 

     is initiated. Press it again the Timer Off indicator 

     light illuminates. It indicates the Auto Stop is 

     initiated.

·    Press or hold the UP or DOWN button to 

     change the Auto time by 0.5 hour increments, 

     up to 10 hours, then at 1 hour increments, up 

     to 24 hours. The control will count down the 

     time remaining until start.

·    The selected time will register in 5 seconds and

     the system will automatically revert back to 

     display the previous humidity setting.

·    When the Auto start & Auto stop times are set,

     within the same program sequence, Timer On

     Off indicator lights illuminate identifying both

     On and Off times are now programmed.

·    Turning the unit On or Off at any time or 

     adjusting the timer setting to 0.0 will cancel 

     the Auto Start/Stop function.

·    When LED display window is plays the code of

     P2, the Auto Start/Stop function will also be

     cancelled. 

Setting the Timer(With 2 indicator lights)

·   

When the unit is on, first press the Timer button, the 

     Timer Off indicator light illuminates. It indicates the

    

·    Turning the unit On or Off at any time or 

     adjusting the timer setting to 0.0 will cancel 

     the Auto Start/Stop function.

·    When LED display window is plays the code of

     P2, the Auto Start/Stop function will also be

     cancelled. 

There are two ways to remove collected water

.

1. Use the bucket
·   When the unit is off,if the bucket is full, the unit will 

    beep 8 times(on some models) and the Full Water 

    indicator light will flash.

·   (For some models)When the unit is on,if the bucket is 

    full, the compressor turns off and the fan turns of f after 

    30 seconds for drying the water of the condenser , then 

    the unit  will beep 8 times and the Full Water indicator 

    light will flash.

·   Slowly pull out the bucket. Grip the left and right

    handles securely , and carefully pull out straight so

    water does not spill. Do not put the bucket on the 

    floor because the bottom of the bucket is uneven. 

    Otherwise the bucket will fall and cause the water to 

    spill. 

·   Throw away the water from the water outlet and 

    replace the bucket. The bucket must  be in place and

    securely seated for the dehumidifier to operate.

·   The machine will re-start when the bucket is restored

    in its correct position.    

 Operating

Instructions

Dryer mode(On some models)

 Page 16 

do not open the door and window.

2. To make the best effective

dehumidification, please first

dehydrate the wet clothes.

3.  Make sure to direct airflow 

at the wet clothes.

4.  For thick and heavy wet 

clothes may not get the best 

effective dehumidification.

Note:

1. The dryer mode must be operated in a close room,

30~50cm 

Wet clothes

30~50cm

Airflow

Allow 30~50cm 

of distance on the 

top and right side 

of the unit to the 

wet clothes.

1. Pull out the bucket  a little.

The unit can make the MAX dehumidification function

when it is under Dryer mode. The fan speed is fixed at 

high fan speed. For some models,The unit will quit dryer 

mode after a maximum 10 hours’ operation. 

Summary of Contents for MDDF-16

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Page 2: ...ance Table of Contents Control Panel Features 12 Other features 15 Clean the grille and case 18 Clean the bucket 18 Troubleshooting Tips 19 Clean the air filter 18 When not using the unit for long tim...

Page 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Page 4: ...been damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut o to avoid damage to the machine due to lightning Do not run cord under carpeting Do not c...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Page 11: ...prior notice Preparation rear front rear front rear front control panel control panel shoes dryer cover shoes dryer pipe drain hose outlet drain hose outlet drain hose outlet power cord buckle power c...

Page 12: ...to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a...

Page 13: ...s Then press pad to operate the desired settings For panel H Indicator Function Indicator Function Timer ON light Timer OFF light Bucket full light Air purifier light Low fan speed light Med fan speed...

Page 14: ...fan control to Normal Note The turbo button is disabled in Dryer mode the Self clean Air purifier or Anti mould functions Pressing the turbo button for more than 3 seconds enables the Self clean funct...

Page 15: ...midity sensor error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service P2 Bucket is...

Page 16: ...on will also be cancelled There are two ways to remove collected water 1 Use the bucket When the unit is off if the bucket is full the unit will beep 8 times on some models and the Full Water indicato...

Page 17: ...the drain hose Select the desired humidity setting and fan speed on the unit for continuous draining to start 2 Continuous draining Note When the continuous drain feature is not being used remove the...

Page 18: ...urely seated for the dehumidifier to operate The air filter behind the front grille should be checked and cleaned at least every two weeks or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTE...

Page 19: ...upright as it should be The floor surface is not level Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The...

Page 20: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...