background image

 Page 15

Other features

Bucket Full Light

Glows when the bucket is ready to be emptied, or 

when the bucket is removed or not replaced in the 

proper position.

Auto Defrost

When forst builds up on the evaporator coils, the

compressor will cycle off and the fan will continue to 

run until the frost disappears.

Note: When Auto defrosting operation, the unit may 

make a voice of refrigerant flowing, it is normal.

proper position.  For some models, the fan motor will 

continue to run for 30 seconds.

Auto Shut Off

The dehumidifier shuts off when the bucket is full, or

when the bucket is removed or not replaced in the

Wait 3 minutes before resuming operation

After the unit has stopped, it can not be restart 

operation in the first 3 minutes.This is to protect the 

unit. Operation will automatically start after 3 minutes.

Setting the Timer(With 1 indicator light)

·    

Press to initiate the Auto start or Auto stop feature, in

      conjuction with the UP and DOWN buttons.

·    When the unit is on, press the Timer button to 

     actieve the Auto Stop feature. When the unit is

     off, press this button to actieve the Auto start 

     feature.

·    Press or hold the UP or DOWN button to 

     change the Auto time by 0.5 hour increments, 

     up to 10 hours, then at 1 hour increments, up 

     to 24 hours. The control will count down the 

     time remaining until start.

·    The selected time will register in 5 seconds and

     the system will automatically revert back to 

     display the previous humidity setting.

Display

Shows the set % humidity level from 35% to 85% or 

auto start/stop time (0~24) while setting, then shows 

the actual(±5% accuracy) room % humidity level in a 

range of 30% RH(Relative Humidity) to 90%RH(Relative 

Humidity).

Error Codes:

AS-Humidity sensor error--Unplug the unit and plug it 

       back in. If error repeats, call for service;

ES-Temperature sensor error-- Unplug the unit and 

       plug it back in. If error repeats, call for service;

P2-Bucket is full or bucket is not in right position-- 

       Empty the bucket and replace it in the right 

       position.

P1-Unit is defrosting--Allow the unit time to 

       automatically service. The protection will clear after 

       the unit self defrosts. (On some models)

E4-Display panel communication error--Unplug the 

      unit and plug it back in. If error repeats, call for 

      service. (On some models)

 Operating

Instructions

reducing the risk of mould and bacterial growth. To 

disable the function, press the Pure pad for 3 seconds 

or select an operating mode with the Mode pad.      

Press the Turbo  pad for 3 seconds to enable this 

function. This function initiates as soon as the unit is 

switched off, and runs 15 minutes under high fan 

speed.   

Self-clean(On some models)

This function significantly reduces the dust, bacteral

and allergen content of the room, using the HEPA(High 

Efficiency Particulate Air) filter supplied with the unit.

Press the Pure pad to activate 

the Air purifier function,

all other modes and special 

functions are inhibited while 

it is running. Make sure you 

have fitted the HEPAfilter as 

indicated in fig.A.

Air purifier function(On some models)

HEPA filter

Air intake grill

Auto-Restart

If the unit breaks off unexpectedly due to the power

cut, it will restart with the previous function setting 

automatically when the power resumes.

Smart dehumidifying mode(On some models)

At smart dehumidifying mode, the unit will 

automatically control room humidity in a comfortable

range 45%~55% according to the room temperature.

The humidity setting function will be invalid.

Anti-mould function(On some models)

Press the Pure pad for 3 seconds to enable this 

function. This maximises occupant comfort while 

Summary of Contents for MDDF-16

Page 1: ...DEHUMIDIFIER Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new machine Make sure to save this manual for future reference...

Page 2: ...ance Table of Contents Control Panel Features 12 Other features 15 Clean the grille and case 18 Clean the bucket 18 Troubleshooting Tips 19 Clean the air filter 18 When not using the unit for long tim...

Page 3: ...the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during oper...

Page 4: ...been damaged contact a technician or customer service for assistance In a thunderstorm the power must be cut o to avoid damage to the machine due to lightning Do not run cord under carpeting Do not c...

Page 5: ...of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehu...

Page 6: ...manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appl...

Page 7: ...able material 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flamma...

Page 8: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Page 9: ...ions on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The fo...

Page 10: ...g order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered r...

Page 11: ...prior notice Preparation rear front rear front rear front control panel control panel shoes dryer cover shoes dryer pipe drain hose outlet drain hose outlet drain hose outlet power cord buckle power c...

Page 12: ...to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a...

Page 13: ...s Then press pad to operate the desired settings For panel H Indicator Function Indicator Function Timer ON light Timer OFF light Bucket full light Air purifier light Low fan speed light Med fan speed...

Page 14: ...fan control to Normal Note The turbo button is disabled in Dryer mode the Self clean Air purifier or Anti mould functions Pressing the turbo button for more than 3 seconds enables the Self clean funct...

Page 15: ...midity sensor error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service P2 Bucket is...

Page 16: ...on will also be cancelled There are two ways to remove collected water 1 Use the bucket When the unit is off if the bucket is full the unit will beep 8 times on some models and the Full Water indicato...

Page 17: ...the drain hose Select the desired humidity setting and fan speed on the unit for continuous draining to start 2 Continuous draining Note When the continuous drain feature is not being used remove the...

Page 18: ...urely seated for the dehumidifier to operate The air filter behind the front grille should be checked and cleaned at least every two weeks or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTE...

Page 19: ...upright as it should be The floor surface is not level Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The...

Page 20: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...

Reviews: