background image

9/16

2009/10 - Indice de révision : C - Code : 0033500

dehumidifiers 850e - 950e

OperatiNg aNd maiNteNaNce iNstructiONs

tO be read carefully aNd kept fOr future refereNce

thaNk-yOu fOr chOOsiNg a climexel dehumidifier. this dOcumeNt describes the device's NumerOus features 

aNd its techNical data. 

please read this dOcumeNt carefully befOre iNstalliNg Or OperatiNg the dehumidifier. 

this maNual shOuld be kept at haNd sO that it may be cONsulted wheN Necessary.

befOre switchiNg the dehumidifier ON fOr the first time, eNsure that it has beeN staNdiNg upright fOr at 

least twO hOurs.    

Summary of Contents for 850E

Page 1: ... a Climexel dehumidifier This document describes the device s numerous FEATURES And its technical data Please read this document carefully before installing or operating the dehumidifier This manual should be kept at hand so that it may be consulted when necessary Before switching the dehumidifier on for the first time ensure that it has been standing upright for at least two hours ...

Page 2: ...the outlet In case of doubt have the installation examined and if necessary modified by a qualified electrician The manufacturer will not be held liable in the event of failure to respect these safety measures Important Never allow current carrying parts to come into contact with water danger of a short circuit The dehumidifier is safe However as with other electrical appliance it should be operat...

Page 3: ...ere it may be damaged by chemicals Where there is a risk of interference by foreign objects This product is not made for DIY repair hoW it WorKs Your CLIMEXEL dehumidifier controls the Relative Humidity by drawing air in and over the cooling elements upon contact with the cold excess moisture in the air condenses out and trickles down This condensate water is channelled into a fixed drain The drie...

Page 4: ...s installed in a pool room connect it to the mains via a transformer or a break switch in accordance with local regulations governing electrical installations Do not open doors or windows unless absolutely necessary while the dehumidifier is running Wall mounting The unit may be placed on the floor or mounted on the wall Make sure that all four feet are touching the ground Wall mounting Fix the su...

Page 5: ...w or high speed setting The corresponding LED 3 indicates the setting selected Lo low or Hi high Digital display 4 The digital display 4 shows relative humidity in the enclosed area Compressor 6 The COMP LED 6 lights up when the compressor is running There is an automatic time delay of three minutes before the compressor re starts working Defrosting The CLIMEXEL 850E 950E dehumidifier features a d...

Page 6: ...er water CAUTION In very cold weather conditions precautions should be taken to prevent the drainage pipe from freezing cleaning Disconnect from the mains before cleaning the unit or any of its components Cleaning the air filter Air circulation is impeded and the efficiency of the dehumidifying and air purifying functions decrease when the filter is dirty It is therefore good practice to clean the...

Page 7: ...ent in operation A 4 5 6 Current upon start up A 18 24 Dehumidification at 32 C RH 90 at 30 C RH 70 L 24h L 24h 65 45 80 60 Refrigernat R407C g 700 750 Air flow rate fan at high speed m3 h 500 680 Ambient temperature C 7 35 Dimensions w x h x d mm 660 x 750 x 345 Weight net kg 39 44 Compliant with EC directive 73 23 CE LVD Specifications may change without prior notice EC No 842 2006 R407C is a pr...

Page 8: ...16 16 2009 10 Indice de révision C Code 0033500 S A au capital de 7 000 000 1 R C S Rennes B 333 263 846 000 37 ...