Page 2: ...Table of Contents Safety Warning 2 Frequent enquiries 3 Installation 4 Components 5 Control Panel 6 Operation Methods 7 Drainage 8 9 Maintenance 10 Troubleshooting 11 ...

Page 3: ...to reduce vibration and noise Keep a distance of at least 50cm between appliances and surroundings Do not place this dehumidifier in water or other liquids In order to prevent accidents please do not use this dehumidifier if wires or other connections aredamaged To stop reset or clean this dehumidifier please cut off the power Please use at the specified voltage This dehumidifier can only be used ...

Page 4: ...d the relative humidity is 30 80 The optimal temperature for use is 16 32 Why has the dehumidifier stopped working won t work Q Frequent enquiries Q Why is hot air blown out from air supply outlet This dehumidifier extracts the air in the room and the dehumidification unit cools the air the temperature decreases below the condensation point the air condenses into water drops which falls into water...

Page 5: ...e reserved around this dehumidifier the minimum distance above is 50cm and the minimum distance in front rear and left right is 20cm as required as shown in figure below If a vibration sound is present during operation of this dehumidifier It is recommended inserting pads or damping rubber sheets etc below this dehumidifier this can reduce vibration and noise and can also reduce sinking of wood fl...

Page 6: ...Handle Filter frame Caster Components Back Drain outlet Power cord storage column Front Water tank cover Water tank handle Water tank Front panel Back panel Control panel ...

Page 7: ...peed In AUTO or CONTINUOUS mode adjust the fan speed HIGH and LOW by pressing this button LCD Display In AUTO CONTINUOUS AND DRYING modes this figure displays room humidity When it is set in AUTO mode this figure shows the set humidity and displays the set time in timer state represents percentage ofhumidity Humidity Setting Once this button is pressed the humidity is displayed circularly in the r...

Page 8: ...ressor will starts and the fan will run at the set speed If the room humidity is lower than the set humidity by 5 then the compressor will stop but the fan will run at the set speed The default set humidity value is 50 CONTINUOUS mode Select CONTINUOUS dehumidification to keep the dehumidifier operating no matter what low the relative humidity in the room is The compressor starts the fan runs at h...

Page 9: ...ater the full water icon on LCD flashes the compressor fan and negative ion will stop running the BUZZER signals 10 times to alert the user to empty the tank respectively at the side of the back cover gently remove the water tank turn the water tank handle upright remove the water tank cover and pour the water out hands both Place Close the tank cover and rotate the water tank handle down then put...

Page 10: ...e water pipe must be more than 10cm lower than the height of the water outlet The water pipe must be kept smooth otherwise the water may not be drained normally dehumidifier to drain water Locate the drain outlet at the back unscrew the drain cover and pull out the water plug Connect the 9mm drainage pipe to the drain outlet 2 1 ...

Page 11: ...long time please disconnect power supply Please clean the water tank and its cover with soft cloth dipped in cold or warm water at regular time to prevent mould inside the dehumidifier Wipe the surface of the dehumidifier slightly with wet cloth and do not use detergent or abrasive in case the plastic surface is damaged Clean the filter and the frame at lease once per two weeks simply with cold or...

Page 12: ...the air filter net blocked Clean the air filter net according to the above method Noise is abnormal during operation Is the dehumidifier placed improperly so that it is inclined or unstable Please place the dehumidifier in smooth place Is the air filter net blocked Clean the air filter net according to the above method There is tittering sound The flowing sound of refrigerant which is a normal phe...