SECTION 5- MAINTENANCE & TROUBLESHOOTING
Note: An authorized CTX service representative must be contacted for any failures that cannot be remedied by
Reprogramming or Rebooting System.
Caution:
Do not remove access panels at the front or rear of oven. High voltage exists inside these
compartments which can cause serious injury or death.
Maintenance:
1.
3
Months
Check and tighten all electrical connections.
Troubleshooting:
A. Chart 1- Error Messages
Display Error Code
Explanation
Corrective Action
OVER TEMP SHUTDN
ZONE#
Over Temperature Error:
This occurs if at least one zone’s
actual temperature exceeds the
maximum allowed temperature of
980
F (526
C)
Call for service
EXT. AMB SHUTDN
External Ambient Error:
This occurs if the external ambient
temperature exceeds 150
F (65
C).
Check axial cooling fan at lower front
of oven for proper operation and
cleanliness. Also it may be the
temperature of the area surrounding
the oven must be reduced. If the fan
is not running call for service.
INT. AMB SHUTDN
Internal Ambient error:
This occurs if the internal ambient
temperature exceeds 150
F (65
C).
Check axial cooling fan at lower front
of oven for proper operation and
cleanliness. Also it may be the
temperature of the area surrounding
the oven must be reduced. If the fan is
not running call for service.
MOTOR JAMMED
Conveyor Jammed:
Conveyor stopped when speed setting
is between 1 and 60 minutes or
conveyor runs full speed.
Clear item that is jamming the
conveyor and/or reset circuit breaker
on the front of the control panel. If
conveyor still does not operate call for
service.
MOTOR RUNAWAY
Conveyor Runaway:
Conveyor runs at full speed.
Check for proper speed setting. If
speed setting is correct call for service.
Summary of Contents for CTX GEMINI Series
Page 46: ...46 Single Belt Conveyor through April 2017 28 8 69776 Extension Tray not shown ...
Page 47: ...47 Single Belt Conveyor Beginning April 2017 ...
Page 48: ...48 Split Belt Conveyor through April 2017 28 8 69776 Extension Tray not ...
Page 49: ...49 Split Belt Conveyor Beginning April 2017 ...
Page 50: ...50 Hearth Belt Conveyor through June 2017 ...
Page 51: ...51 Hearth Belt Conveyor beginning June 2017 ...
Page 52: ...52 SECTION 7 SCHEMATICS A DZ33I EMS AND Hi Temp Voltage and Amperage Schedule ...
Page 53: ...53 B DZ33I 208 240V 3Ph Schematic ...
Page 54: ...54 C DZ33I 208 240V 3 Phase to 1 Phase Conversion ...
Page 55: ...55 D DZ33I 380 416V 3 Ph Schematic ...
Page 56: ...56 E DZ33I 230V CE 3 Ph Schematic ...
Page 57: ...57 F DZ33I 380V CE 3 Ph Schematic ...
Page 58: ...58 Notes ...