37
SECTION 4- CLEANING
Frequent cleaning will help your oven operate at peak performance and efficiency.
Keep your oven clean!
A. Cleaning the Cooling Fan Filter
The foam filter and the protective grille of the cooling fan should be cleaned weekly. Daily cleaning may be required if
contaminants have built up on filter. Snap the protective grille off and wipe clean with a cloth. Remove the foam filter and
inspect it. If dusty, shake briskly. If there is greasy dirt, gently wash in warm soapy water, rinse, squeeze and set aside to
dry completely. Reinstall filter and grille.
CAUTION:
Electrical Components are directly behind the
cooling fan.
BE SURE filter is dry before reinstalling.
B. Oven Cleaning Operation
CTX series oven features a self-cleaning cycle already programmed into the control. When the cleaning cycle is
engaged the control automatically increases all heat zones to 900°F (482°C). When all four hearing zones are at
900
the control will count down from 60:00 till it reaches 00:00 minutes. At the conclusion of the cycle the control
returns the oven chamber to the status in effect prior to engagement of the cleaning cycle. If the oven is
programmed to shut OFF (timing Mode) during the CLEAN cycle the CLEAN Mode will override program and
continue at 900°F (282°C) for the full 60 minutes. Oven will then shut OFF in Timing Mode.
. Cleaning Operation
Step
Press
Key
Display
Reads
1. Push and hold for 2 seconds to
start cleaning operation
2. Display will count up from 60:00
to 00:00
3. After the Clean cycle has completed
the preset menu prior to the Cleaning
cycle is re-initiated
Summary of Contents for CTX GEMINI Series
Page 46: ...46 Single Belt Conveyor through April 2017 28 8 69776 Extension Tray not shown ...
Page 47: ...47 Single Belt Conveyor Beginning April 2017 ...
Page 48: ...48 Split Belt Conveyor through April 2017 28 8 69776 Extension Tray not ...
Page 49: ...49 Split Belt Conveyor Beginning April 2017 ...
Page 50: ...50 Hearth Belt Conveyor through June 2017 ...
Page 51: ...51 Hearth Belt Conveyor beginning June 2017 ...
Page 52: ...52 SECTION 7 SCHEMATICS A DZ33I EMS AND Hi Temp Voltage and Amperage Schedule ...
Page 53: ...53 B DZ33I 208 240V 3Ph Schematic ...
Page 54: ...54 C DZ33I 208 240V 3 Phase to 1 Phase Conversion ...
Page 55: ...55 D DZ33I 380 416V 3 Ph Schematic ...
Page 56: ...56 E DZ33I 230V CE 3 Ph Schematic ...
Page 57: ...57 F DZ33I 380V CE 3 Ph Schematic ...
Page 58: ...58 Notes ...