16
I. Electrical
Connection
All wiring and electrical connections required
for the oven(s) must be performed by a
certified electrician. Each oven must be wired
according to the electrical specification for the
oven rating. See charts in Section 1, electrical
schematic in Section 7 and schematics
furnished with the oven. A separate ground wire
must be supplied with each oven. Conduit may
not be used as ground. Consult national or local
electrical codes for wire gauge and circuit
breaker ratings.
CAUTION: All DZ Series Ovens are manufactured
for voltage specific operation.
IMPORTANT:
ALWAYS carefully check the data
plate voltage rating to be sure which voltage to apply
when installing a DZ Series oven. Applying the
wrong voltage can immediately damage oven.
If local codes allow, we recommend that flexible
conduit be used for final connection as the oven
assembly is on casters and the use of flexible
conduit will allow movement for cleaning.
J. Loose
Parts
The aluminum crumb trays (PN 67932) (2 per
oven) are shipped mounted in place. They are
removable for cleaning and are considered
loose parts. They should be checked prior to
startup to be sure they are properly in place.
The stainless steel draft curtain and exit
shelves are packed in a separate carton inside
oven.
NOTE: Make sure protective plastic film is removed
from draft curtains before installation.
1.
Draft Curtains,
stainless steel (PN
322904) (2 per oven). These mount above
the conveyor at the ends of the cooking
chamber. They serve to reduce drafts
through the oven chamber and to reduce
heat loss to the environment. To install,
locate the thin rod above each entrance/exit
of the oven. Hang one draft curtain over
each rod. They are in their lowest position
when hanging vertical. To raise the curtains
to their highest position, swing them outward
until they are horizontal and then push in
toward oven chamber.
NOTE:
Make sure protective plastic film is
removed from exit shelves before installation.
2.
Exit Shelves,
stainless steel (PN
69776) (2 per oven). These shelves
mount in cantilever fashion at the exit
and entrance end of the conveyor and
provide a landing zone for cooked
product. Depending on the operation
they may or may not be needed or used.
To install, place the slotted end of the
shelf over the crossbar at the end of the
conveyor extension frame.
Summary of Contents for CTX GEMINI Series
Page 46: ...46 Single Belt Conveyor through April 2017 28 8 69776 Extension Tray not shown ...
Page 47: ...47 Single Belt Conveyor Beginning April 2017 ...
Page 48: ...48 Split Belt Conveyor through April 2017 28 8 69776 Extension Tray not ...
Page 49: ...49 Split Belt Conveyor Beginning April 2017 ...
Page 50: ...50 Hearth Belt Conveyor through June 2017 ...
Page 51: ...51 Hearth Belt Conveyor beginning June 2017 ...
Page 52: ...52 SECTION 7 SCHEMATICS A DZ33I EMS AND Hi Temp Voltage and Amperage Schedule ...
Page 53: ...53 B DZ33I 208 240V 3Ph Schematic ...
Page 54: ...54 C DZ33I 208 240V 3 Phase to 1 Phase Conversion ...
Page 55: ...55 D DZ33I 380 416V 3 Ph Schematic ...
Page 56: ...56 E DZ33I 230V CE 3 Ph Schematic ...
Page 57: ...57 F DZ33I 380V CE 3 Ph Schematic ...
Page 58: ...58 Notes ...