4-3
Calibration
Calibration Options
This command specifies the operation of the imager’s calibration feature. The default
configuration is set up to perform calibration on gain, focus, and symbol type. The
default shutter speed setting is disabled, because not all applications require shutter
speed, and when it is required, the application-specific settings tend to vary widely.
Note:
Background Color
is part of the calibration process regardless of the calibration
setup. After successful completion of the calibration routine, the background color will be
set to the appropriate value, depending on the symbol in the field of view. The
Illumination
Brightness
parameter is not part of the calibration process, and it must be configured
appropriately
prior to calibration.
Gain
Shutter Speed
Note:
The following table shows general guidelines for shutter speed configurations based on
various line speeds. The configurations shown depend on the imager’s optical configuration,
and on symbol element size.
Definition:
When enabled, gain will be calibrated to provide the best available image
quality and performance.
When disabled, gain is fixed and is not part of the calibration process.
Serial Cmd:
<
K529,
gain
,shutter speed,symbol type,WOI framing,WOI margin,line
scan height,processing
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Definition:
Unless an application is a static setup, the shutter speed setting should be
configured by the user based on the application. For dynamic applications, the
user should configure the shutter speed setting so the calibration process can
optimize the gain for that setting.
Serial Cmd:
<
K529,
gain,
shutter speed
,symbol type,WOI framing,WOI margin,line
scan height,processing
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
2 = Fast Shutter
Shutter Speed
Line Speed
0 - 250
static
250 - 750
5” / sec
750 - 1500
10” / sec
1500 - 2000
15” / sec
2000 - 2500
20” / sec
Summary of Contents for MS-4Xi
Page 1: ...MS 4Xi Imager User Manual P N 84 004444 Rev A ...
Page 12: ...xii MS 4Xi Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 MS 4Xi Imager User s Manual Save Configuration in ESP ...
Page 44: ...2 18 MS 4Xi Imager User s Manual Using EZ Trax ...
Page 64: ...3 20 MS 4Xi Imager User s Manual Postamble ...
Page 110: ...5 28 MS 4Xi Imager User s Manual Setting Up the Imager for EZ Trax ...
Page 152: ...6 42 MS 4Xi Imager User s Manual Background Color ...
Page 256: ...10 30 MS 4Xi Imager User s Manual Morphological Operation and Operator Size ...
Page 306: ...13 26 MS 4Xi Imager User s Manual Other Operational Serial Commands ...
Page 329: ...MS 4Xi Imager User s Manual A 9 Appendices PNP Output for Host Input ...
Page 330: ...A 10 MS 4Xi Imager User s Manual Communication Protocol Commands PNP Output for External Load ...
Page 332: ...A 12 MS 4Xi Imager User s Manual Electrical Specifications PNP ...
Page 333: ...MS 4Xi Imager User s Manual A 13 Appendices Output Wiring ...