MS-4Xi Imager User’s Manual
9-11
Matchcode
Mismatch Replace
Replacement String
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For
<
:
<K736h,,3C>
For
>
:
<K736h,,3E>
For
,
:
<K736h,,2C>
Usage:
Provides a convenient shortcut for applications that need to output a
predefined text string whenever a symbol does not match a master
symbol.
Definition:
Outputs a user-defined data string whenever a mismatch occurs and
Matchcode
is enabled.
Serial Cmd:
<
K736,
status
,replacement string
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
User-defined data string that, when enabled, replaces symbol data
whenever a mismatch occurs.
Serial Cmd:
<
K736,
status,
replacement string
>
Default:
MISMATCH
Options:
An ASCII string up to 64 characters.
Summary of Contents for MS-4Xi
Page 1: ...MS 4Xi Imager User Manual P N 84 004444 Rev A ...
Page 12: ...xii MS 4Xi Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 MS 4Xi Imager User s Manual Save Configuration in ESP ...
Page 44: ...2 18 MS 4Xi Imager User s Manual Using EZ Trax ...
Page 64: ...3 20 MS 4Xi Imager User s Manual Postamble ...
Page 110: ...5 28 MS 4Xi Imager User s Manual Setting Up the Imager for EZ Trax ...
Page 152: ...6 42 MS 4Xi Imager User s Manual Background Color ...
Page 256: ...10 30 MS 4Xi Imager User s Manual Morphological Operation and Operator Size ...
Page 306: ...13 26 MS 4Xi Imager User s Manual Other Operational Serial Commands ...
Page 329: ...MS 4Xi Imager User s Manual A 9 Appendices PNP Output for Host Input ...
Page 330: ...A 10 MS 4Xi Imager User s Manual Communication Protocol Commands PNP Output for External Load ...
Page 332: ...A 12 MS 4Xi Imager User s Manual Electrical Specifications PNP ...
Page 333: ...MS 4Xi Imager User s Manual A 13 Appendices Output Wiring ...