7-40
MS-4Xi Imager User’s Manual
Quality Output
Quality Output
Separator
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For
<
:
<K704h,3C>
For
>
:
<K704h,3E>
For
,
:
<K704h,2C>
Decodes per Trigger Status
Definition:
The separator character separates quality output data from symbol data.
Serial Cmd:
<
K704,
separator
,decodes per trigger status
>
Default:
,
Options:
Any ASCII character.
Definition:
When this feature is enabled, the imager enters a state where it processes
frames as configured until the end of a read cycle, with or without a successful
symbol decode. When the read cycle ends, the imager outputs any
decoded symbol data along with the decodes per trigger count.
Serial Cmd:
<
K704,
separator,
decodes per trigger status
>
Default:
0
Options:
0 = Disabled
1 = Enabled
Summary of Contents for MS-4Xi
Page 1: ...MS 4Xi Imager User Manual P N 84 004444 Rev A ...
Page 12: ...xii MS 4Xi Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 MS 4Xi Imager User s Manual Save Configuration in ESP ...
Page 44: ...2 18 MS 4Xi Imager User s Manual Using EZ Trax ...
Page 64: ...3 20 MS 4Xi Imager User s Manual Postamble ...
Page 110: ...5 28 MS 4Xi Imager User s Manual Setting Up the Imager for EZ Trax ...
Page 152: ...6 42 MS 4Xi Imager User s Manual Background Color ...
Page 256: ...10 30 MS 4Xi Imager User s Manual Morphological Operation and Operator Size ...
Page 306: ...13 26 MS 4Xi Imager User s Manual Other Operational Serial Commands ...
Page 329: ...MS 4Xi Imager User s Manual A 9 Appendices PNP Output for Host Input ...
Page 330: ...A 10 MS 4Xi Imager User s Manual Communication Protocol Commands PNP Output for External Load ...
Page 332: ...A 12 MS 4Xi Imager User s Manual Electrical Specifications PNP ...
Page 333: ...MS 4Xi Imager User s Manual A 13 Appendices Output Wiring ...