6-22
MS-4Xi Imager User’s Manual
Codabar
Check Character Type (Codabar)
Check Character Output (Codabar)
Definition:
When disabled, the imager will not perform any character checking calculations
on decoded Codabar symbols.
When set to
Mod 16
, the imager will perform a modulus 16 check character
calculation on the symbol. If the symbol does not pass this calculation, it
will not be decoded.
When set to
NW7
, The imager will perform an NW7 modulus 11 check character
calculation on the symbol. If the symbol does not pass this calculation, it will not
be decoded.
When set to
Both
, the imager will perform both the Mod 16 and NW7 modulus
11 check character calculations on the symbol. If the symbol does not pass
either calculation, it will not be decoded.
Serial Cmd:
<
K471,
status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,
check character type
,check character
output
>
Default:
Disabled
Options:
0 = Disabled
1 = Mod 16
2 = NW7 (Mod 11)
3 = Mod 16 and NW7
Definition:
When this field is disabled and a check character calculation is enabled,
the imager will strip the verified check character from the symbol data out-
put. This condition must be accounted for if a fixed length is also being
used.
When enabled, the imager will output the check character as part of the
symbol data. This condition must be accounted for if a fixed length is also
being used.
Serial Cmd:
<
K471,
status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,check character type,
check character
output
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for MS-4Xi
Page 1: ...MS 4Xi Imager User Manual P N 84 004444 Rev A ...
Page 12: ...xii MS 4Xi Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 MS 4Xi Imager User s Manual Save Configuration in ESP ...
Page 44: ...2 18 MS 4Xi Imager User s Manual Using EZ Trax ...
Page 64: ...3 20 MS 4Xi Imager User s Manual Postamble ...
Page 110: ...5 28 MS 4Xi Imager User s Manual Setting Up the Imager for EZ Trax ...
Page 152: ...6 42 MS 4Xi Imager User s Manual Background Color ...
Page 256: ...10 30 MS 4Xi Imager User s Manual Morphological Operation and Operator Size ...
Page 306: ...13 26 MS 4Xi Imager User s Manual Other Operational Serial Commands ...
Page 329: ...MS 4Xi Imager User s Manual A 9 Appendices PNP Output for Host Input ...
Page 330: ...A 10 MS 4Xi Imager User s Manual Communication Protocol Commands PNP Output for External Load ...
Page 332: ...A 12 MS 4Xi Imager User s Manual Electrical Specifications PNP ...
Page 333: ...MS 4Xi Imager User s Manual A 13 Appendices Output Wiring ...