9-6
MS-4Xi Imager User’s Manual
Matchcode Type
Sequential Matching
Match Start Position
Note: Match Start Position
must be set to
1
or greater to enable this feature. A
0
setting
will disable this feature.
Match Length
Usage:
Useful in tracking product serial numbers that increment or decrement
sequentially.
Definition:
With Sequential enabled, Sequential Matching determines if a count is in
ascending (incremental) or descending (decremental) order.
Serial Cmd:
<
K223,
matchcode type,
sequential matching
,match start position,match
length,wild card character,sequence on No Read,sequence on mismatch
>
Default:
Increment
Options:
0 = Increment
1 = Decrement
Usage:
Match Start Position
is useful in defining specific portions of a symbol
for comparison. For example, if a symbol contains a part number, manufacturing
date, and lot code info, but you are only interested in the part number
information, you can set the imager to sort only the part number and
ignore the other characters.
Definition:
Match Start Position
determines the portions of symbols that will be
matched by defining the first character in the symbol (from left to right)
that will be compared with those of the master symbol, when
Matchcode
Type
is set to
Enabled
or
Sequential
.
Function:
For example, if
Match Start Position
is set to
3
, the first 2 characters
read in the symbol will be ignored and only the 3rd and subsequent
characters to the right will be compared, up to the number of characters
specified by
Match Length
.
Serial Cmd:
<
K223,
matchcode type,sequential matching,
match start position
,
match length,wild card character,sequence on No Read,sequence on
mismatch
>
Default:
0
Options:
0 to 3000
Usage:
Example:
If
Match Length
is set to
6
in a 10-character symbol, and
Match Start Position
is set to
2
, only the 2nd through 7th characters
(from left to right) will be compared.
Definition:
Defines the length of the character string that will be compared with that
of the master symbol when
Match Start Position
is set to
1
or greater.
When
Match Start Position
is set to
0
, no comparison will occur.
Serial Cmd:
<
K223,
matchcode type,sequential matching,match start position,
match
length
,wild card character,sequence on No Read,sequence on mismatch
>
Default:
1
Options:
1 to 3000
Summary of Contents for MS-4Xi
Page 1: ...MS 4Xi Imager User Manual P N 84 004444 Rev A ...
Page 12: ...xii MS 4Xi Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 MS 4Xi Imager User s Manual Save Configuration in ESP ...
Page 44: ...2 18 MS 4Xi Imager User s Manual Using EZ Trax ...
Page 64: ...3 20 MS 4Xi Imager User s Manual Postamble ...
Page 110: ...5 28 MS 4Xi Imager User s Manual Setting Up the Imager for EZ Trax ...
Page 152: ...6 42 MS 4Xi Imager User s Manual Background Color ...
Page 256: ...10 30 MS 4Xi Imager User s Manual Morphological Operation and Operator Size ...
Page 306: ...13 26 MS 4Xi Imager User s Manual Other Operational Serial Commands ...
Page 329: ...MS 4Xi Imager User s Manual A 9 Appendices PNP Output for Host Input ...
Page 330: ...A 10 MS 4Xi Imager User s Manual Communication Protocol Commands PNP Output for External Load ...
Page 332: ...A 12 MS 4Xi Imager User s Manual Electrical Specifications PNP ...
Page 333: ...MS 4Xi Imager User s Manual A 13 Appendices Output Wiring ...