MS-4Xi Imager User’s Manual
5-23
Read Cycle
Image Processing Timeout
Notes:
• The timeout period does not include capture time.
• If a timeout occurs during processing and no symbols in the field of view have been
decoded, the image will be recorded as a No Read. For this reason, a longer timeout
should be tried to ensure that the symbol is decoded successfully.
Usage:
Useful in higher speed applications where image processing time is long
enough that not all captures have an opportunity to be processed.
Definition:
Specifies the maximum amount of time to process a captured image.
When the timeout expires, the image processing is aborted. This timeout
works in both
Rapid Capture
and
Continuous Capture
modes, as well
as with the Configuration Database.
Serial Cmd:
<
K245,
image processing timeout
>
Default:
5000 ms
(5 sec.)
Options:
1 to 65535 (in 1 ms increments)
Summary of Contents for MS-4Xi
Page 1: ...MS 4Xi Imager User Manual P N 84 004444 Rev A ...
Page 12: ...xii MS 4Xi Imager User s Manual Statement of RoHS Compliance ...
Page 26: ...1 14 MS 4Xi Imager User s Manual Save Configuration in ESP ...
Page 44: ...2 18 MS 4Xi Imager User s Manual Using EZ Trax ...
Page 64: ...3 20 MS 4Xi Imager User s Manual Postamble ...
Page 110: ...5 28 MS 4Xi Imager User s Manual Setting Up the Imager for EZ Trax ...
Page 152: ...6 42 MS 4Xi Imager User s Manual Background Color ...
Page 256: ...10 30 MS 4Xi Imager User s Manual Morphological Operation and Operator Size ...
Page 306: ...13 26 MS 4Xi Imager User s Manual Other Operational Serial Commands ...
Page 329: ...MS 4Xi Imager User s Manual A 9 Appendices PNP Output for Host Input ...
Page 330: ...A 10 MS 4Xi Imager User s Manual Communication Protocol Commands PNP Output for External Load ...
Page 332: ...A 12 MS 4Xi Imager User s Manual Electrical Specifications PNP ...
Page 333: ...MS 4Xi Imager User s Manual A 13 Appendices Output Wiring ...