U1000MKII User Manual
Micronics
Page 36
Issue 3.1 July 19
4.4.2
Select Slave Function
COMMAND:
SEND_NKE
DESCRIPTION:
Initialise / Reset slave device for communications.
DIRECTION:
MASTER TO SLAVE
FRAME TYPE:
SHORT / LONG FRAME
PRIMARY ADDRESSING
SECONDARY ADDRESSING
NAME
CODE
NAME
CODE
START
0x10
START
0x68
(C - FIELD)
INITIALISE SLAVE
0x40
LENGTH
0x0B
(A - FIELD)
SLAVE PRIMARY ADDRESS
0xXX
LENGTH
0x0B
CHECKSUM
0xXX
START
0x68
STOP
0x16
(C
–
FIELD)
INITIALISE SLAVE
0x73
(A
–
FIELD)
USE SECONDARY ADDRESSING
0xFD
(CI
–
FIELD)
INITIALISE SLAVE
0x52
M-Bus IIN (BYTE 1)
0xXX
M-Bus IIN (BYTE 2)
0xXX
M-Bus IIN (BYTE 3)
0xXX
M-Bus IIN (BYTE 4)
0xXX
MANF. ID (BYTE 1)
0xCD
MANF. ID (BYTE 2)
0x54
VERSION NUMBER
0x01
DEVICE TYPE ID
0x04
CHECKSUM
0xXX
STOP
0x16
MASTER TO SLAVE: SEND_NKE
SLAVE TO MASTER: ACK
4.4.3
Data Transfer Functions
No
VARIABLE
TYPE
SELECTION BITS
1
FLOW RATE
IEEE754 FLOAT
LITRES / MINUTE
2
ENERGY
IEEE754 FLOAT
kWh
3
POWER
IEEE754 FLOAT
kW
4
TEMPERATURE (COLD)
IEEE754 FLOAT
CELCIUS
5
TEMPERATURE (HOT)
IEEE754 FLOAT
CELCIUS
6
TEMPERATURE (DIFFERENCE)
IEEE754 FLOAT
CELCIUS