![Microcom 438TM Operator'S Manual Download Page 164](http://html1.mh-extra.com/html/microcom/438tm/438tm_operators-manual_1786158164.webp)
Bar Codes
Chapter 8
8-28
438TM Operator’s Manual - 880049-0113
Minimum Err Correction
0
Auto
1
20%
2
37%
3
55%
4
65%
Table 8-13 QR Code Minimum Error Correction
Mode - 0
This parameter is used to set the mode to be used in generating the Aztec barcode. A
value of 0 generates a standard Aztec while a setting of 2 would use the GS1 specification.
Please note that if the GS1 is used, the application identifiers should be entered with
brackets, Example: [21]123.
Modes
0
Standard
1
Reserved
2
GS1*
Table 8-14 QR Code Modes
8.2 Bar Code Rotation
When 0 and 180 degree bar codes are X multiplied (CMX), the space between characters is
also multiplied by the printer internally to maintain the correct ratio. When multiplying bar
codes use the default value for the spacing element (SP) in the field format parameters. On
some bar codes that allow spacing to be adjusted, spacing may be increased from the
default and not reduced to a smaller spacing.
When 0 and 180 degree bar codes are Y multiplied (CMY), the result is the actual height of
the bar code in thermal dots. If the Y multiplier (CMY) is not multiplied, a bar code with a
vertical length of one dot would be produced. For example: If a one inch high bar code is
desired using a 300 dpi print head, 300 should be inserted for the CMY value.
When 90 and 270 degree, ladder or vertical, bar codes are X multiplied (CMX), the result is
the actual width of the bar code in thermal dots. If the X multiplier (CMX) is not multiplied, a
bar code with a horizontal length of one dot would be produced. For example: If a one inch
wide bar code is desired using a 300 dpi print head, 300 should be inserted for the CMX
value.
When 90
°
and 270
°
degree bar codes are Y multiplied (CMY), the space between
characters is also multiplied by the printer internally to maintain the correct ratio. When
multiplying bar codes use the default value for the spacing element (SP) in the field format
parameters. On some bar codes that allow spacing to be adjusted, spacing may be
increased from the default and not reduced to a smaller spacing.
Summary of Contents for 438TM
Page 2: ......
Page 4: ......
Page 8: ...438TM Operator s Manual 880049 0113 iv...
Page 54: ...Getting Started Chapter 3 3 42 438TM Operator s Manual 880049 0113...
Page 124: ...Printer Commands Chapter 5 5 56 438TM Operator s Manual 880049 0113...
Page 130: ...Downloadable Graphics Chapter 6 6 6 438TM Operator s Manual 880049 0113...
Page 136: ...Downloadable Fonts Chapter 7 7 6 438TM Operator s Manual 880049 0113...
Page 168: ...Bar Codes Chapter 8 8 32 438TM Operator s Manual 880049 0113...
Page 174: ...Code Switching Chapter 9 9 6 438TM Operator s Manual 880049 0113 Figure 9 5 Code Page 850...
Page 178: ...Code Switching Chapter 9 9 10 438TM Operator s Manual 880049 0113 Figure 9 9 Code Page 852...
Page 182: ...Code Switching Chapter 9 9 14 438TM Operator s Manual 880049 0113 Figure 9 13 Code Page 437...
Page 186: ...Code Switching Chapter 9 9 18 438TM Operator s Manual 880049 0113...
Page 208: ...13 2 438TM Operator s Manual 880049 0113...
Page 210: ...13 4 438TM Operator s Manual 880049 0113...
Page 230: ...13 24 438TM Operator s Manual 880049 0113...
Page 231: ......