![Microcom 428LT Operator'S Manual Download Page 82](http://html1.mh-extra.com/html/microcom/428lt/428lt_operators-manual_1786151082.webp)
Chapter 5
Printer Commands
428LT Operator’s Manual - 880040-0200 5-39
issued before the ^D3 command. The only difference between this command
and the ^D73 is the ability to increment and/or decrement sequential numbers
in a batch.
XXX 76
Load Delay Time Between Printed Labels:
Delays the printing between
labels in a batch. The “^Axxx” specifies the delay time in tenths of a second
with a maximum value of 650. For example, “^A10^D76<CR>” would
introduce a one second delay between printed labels. This command is
typically used in conjunction with the Peel-n-Dispense mode and applicators.
5.7 Label Header Parameter Override Commands
It is possible to override label header parameters by adding one or more of the following
commands after the label format.
^A
^D
COMMAND
40
Clears Commands 41 through 51
XX
41
Load Number of Fields in Layout (HFM):
The ^Axx specifies the value.
XX
42
Load Label Width in dots (LSX):
The ^Axx specifies the value.
XX
43
Load Label Height in dots (LSY):
The ^Axx specifies the value.
XX
44
Load the Web Size in dots (WEB):
The ^Axx specifies the value.
XX
45
Load the Gap Size in dots (GAP):
The ^Axx specifies the value.
XX
46
Load Print Speed:
The ^Axx specifies the value.
XX
47
Load the Label Control Byte (LCB):
The ^Axx specifies the value.
XX
48
Load the Number of Steps to Activate Gap Detector (AGD):
The ^Axx
specifies the value in Dot Rows.
XX
49
Load the Number of Steps Past Gap (SPG):
The ^Axx specifies the value
in Dot Rows.
XX
50
Load X Direction Offset (OFX):
The ^Axx specifies the value.
XX
51
Load Y Direction Offset (OFY):
The ^Axx specifies the value.
5.7.1
Serial Number Commands
The following commands, ^D80 through ^D89, are used for the serial number function
commands of the printer. The printer can increment or decrement any single serial number
on the label by any amount. If the format contains more than one serial number, then all
serial number fields can only increment or decrement by a value of one. Single and Multiple
serial number commands cannot be used on the same format. Please note that the ^D57
command clears most of the serial number commands. Therefore, all serial number
commands should be placed after the ^D56 command or just prior to the ^D3 command.
Summary of Contents for 428LT
Page 2: ......
Page 4: ......
Page 12: ...viii 428LT Operator s Manual 880040 0200...
Page 117: ...Downloadable Fonts Chapter 7 7 8 428LT Operator s Manual 880040 0200...
Page 151: ...Code Switching Chapter 9 9 6 428LT Operator s Manual 880040 0200 Figure 9 5 Code Page 850...
Page 155: ...Code Switching Chapter 9 9 10 428LT Operator s Manual 880040 0200 Figure 9 9 Code Page 852...
Page 159: ...Code Switching Chapter 9 9 14 428LT Operator s Manual 880040 0200 Figure 9 13 Code Page 437...
Page 163: ...Code Switching Chapter 9 9 18 428LT Operator s Manual 880040 0200...
Page 183: ...13 10 428LT Operator s Manual 880040 0200...
Page 185: ...12 2 428LT Operator s Manual 880040 0200...
Page 187: ...12 4 428LT Operator s Manual 880040 0200...
Page 207: ...12 24 428LT Operator s Manual 880040 0200...
Page 209: ......
Page 210: ......