Summary of Contents for optoCONTROL 1202

Page 1: ...optoCONTROL 1202 75 optoCONTROL 1202 100 Instruction Manual optoCONTROL 1202...

Page 2: ...ec GmbH Manfred W rner Stra e 101 73037 G ppingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com Certified acc to DIN EN ISO 9001 2008 Non cont...

Page 3: ...king Included in Delivery 13 4 2 Storage 13 5 Installation and Mounting 14 5 1 Sensor Mounting 14 5 2 Electrical Connections 19 5 2 1 Power Supply Inputs and Outputs 21 5 2 2 Serial Interface 23 6 Ope...

Page 4: ...optoCONTROL 1202 7 Calibration 32 8 Warranty 32 9 Service Repair 32 10 Decommissioning Disposal 33 11 Optional Accessories 33 12 Factory Setting 34...

Page 5: ...a user tip 1 2 Warnings Caution use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Connect the power supply and t...

Page 6: ...channel Use protective housings Damage to transmitter receiver 1 3 Notes on CE Identification The following applies to optoCONTROL 1202 EU directive 2014 30 EU EU directive 2011 65 EU RoHS category 9...

Page 7: ...operated within the limits specified in the technical data see Chap 3 2 Use it in such a way that with malfunctions or total failure of the sensor persons are not endangered and machines are not damag...

Page 8: ...nt without further protective measures Class 1 lasers are not subject to registration and a laser protection officer is not required The laser warning label for Germany is included in delivery The ver...

Page 9: ...one of the measuring object As a result the pixels within the shadow zone give off a considerably lower analog voltage compared to the illu minated pixels By means of suitable software algorithms the...

Page 10: ...to transmitter TEACH RESET key Input IN1 Potentiometer tolerance specification LED display red green red yellow STATUS DIGITAL OUT1 LED red LED green Measuring value in tolerance specification LED re...

Page 11: ...ssible external light 5000 Lux 5 Housing material aluminum anodized in black Housing dimensions without flange female connector transmitter LxWxH approx 130x125x30 mm receiver LxWxH approx 75x125x30 m...

Page 12: ...age Ub 0 V with protective circuit IN1 teach Reset input voltage Ub 0 V with protective circuit Power supply 15 VDC 30 VDC typ 200 mA Sensitivity adjustment using Windows via PC parameterization softw...

Page 13: ...iately after unpacking The delivery includes 1 Transmitter ODC1202 x T 1 Instruction manual 1 Receivcer ODC1202 x R 1 Software manual 1 Product CD In case of damage or missing parts please contact Mic...

Page 14: ...existing holes on a flat surface Clamps of any kind are not permitted Inaccurate erroneous measuring values Mount the transmitter and receiver above every the three through holes dia 4 5 or above eve...

Page 15: ...1202 75 T 7 1 M5 4 ODC1202 75 R 7 1 M5 4 ODC1202 100 T 7 1 M5 4 ODC1202 100 R 7 1 M5 4 1 Screw in depth sustaining thread length 2 6 Recommended tightening torque max 10 valid min 20 do not fall below...

Page 16: ...ion on the alignment of target for avoiding measurement inaccuracies see Fig 3 Fig 3 Measurement inaccuracy at tilted targets Do not touch the optical windows Contamination on the optical windows impa...

Page 17: ...1 57 80 3 14 30 1 19 20 0 79 30 1 18 20 0 79 M5 8 deep 10 0 39 35 1 38 optoCONTROL 1202 75 Transmitter optoCONTROL 1202 75 Receiver 75 2 95 4 5 d i a 4 5 7 5 0 29 112 4 40 74 9 2 95 125 4 92 40 1 57 1...

Page 18: ...1 18 70 2 76 30 1 18 20 0 79 30 1 18 20 0 79 M5 8 deep 10 0 39 35 1 38 optoCONTROL 1202 100 Transmitter optoCONTROL 1202 100 Receiver 75 2 95 4 5 d i a 4 5 9 5 0 37 130 5 11 97 5 3 84 145 5 70 40 1 5...

Page 19: ...4 pin female connector Binder series 707 RS232 3 pin female connector Binder series 712 connection to transmitter Fastening screw thread M5 8 mm deep Transmit optics Mounting hole dia 4 5 Mounting ho...

Page 20: ...gnal gray OUT0 V yellow IN1 green IN0 ODC1202 x T Transmitter ODC1202 x R Receiver 1 Fig 7 Typical wiring of transmitter receiver control the digital input IN1 and the digital output OUT0 Bending radi...

Page 21: ...202 x 1 2 3 4 5 6 7 8 View on solder pin side male cable connector 1 Ground 0 V white 2 Power supply 15 30 VDC brown 3 INO External trigger green 4 IN1 Teach Reset yellow 5 OUT0 grey 6 OUT1 pink 7 OUT...

Page 22: ...Digital outputs OUT0 OUT2 Characteristics High side low side switch HIGH Ub 12 32 VDC LOW 0 V max 0 1 A short circuit proof The polarity of the digital outputs can only be changed via the parameter PO...

Page 23: ...707 As matching part you require an adequate cable connector Different converted cables are optionally available The optional available interface cables SCD1202 x feature following bending radii 53 m...

Page 24: ...Teach Reset key for teaching of setpoint value respectively reset of maximum values function like input IN1 Potentiometer for tolerance setting Turning the potentiometer clockwise increases the toler...

Page 25: ...ofile of the CCD line is evaluated SMR EMR SMR EMR R EDGE The first detected edge in the intensity profile of the CCD line is evaluated SMR EMR SMR EMR WIDTH The difference between the last edge and t...

Page 26: ...e 74 9 mm Value 34 45 mm SMR EMR SMR EMR SMR EMR 0 V Transmitter Receiver Receiver fully exposed 0 100 Measuring range Receiver completely blocked 10 V The system outputs 0 V if no object blocks any l...

Page 27: ...ut is set Also LED s on the receiver indicate the states of the digital outputs Thereto a measuring window must be parameterized The setup is ef fected at the receiver via the Teach key and the tolera...

Page 28: ...ple is active The respectively actual MAX MIN value is inside this window output at pin 8 red If the HIGH pulse is reset on IN0 the during the window detected MAX MIN value persists on the analog outp...

Page 29: ...unction IN1 When a HIGH pulse of more than 1 5 s duration is applied at Input IN1 see Fig 14 the TEACH function is performed at the receiver If the receiver detects a TEACH pulse the yellow LED at the...

Page 30: ...D ALONE mode without PC Functions of the software Visualization of measurement data in numeric and graphic output fields Setting of the laser power for the laser transmitter Setting of the polarity of...

Page 31: ...hic display the intensity profile is shown as a red curve The numerical values 1 1024 on the x axis represent the individual pixels of the CCD line The ana log values of the CCD line are converted by...

Page 32: ...hird parties No other claims except as warranted are accepted The terms of the purchasing contract apply in full MICRO EPSILON Eltrotec will specifically not be responsible for eventual consequential...

Page 33: ...r receiver length 5 m SCD1202 2 RS232 Digital output cable for connection to an interface RS232 length 2 m SCD1202 5 RS232 Digital output cable for connection to an interface RS232 length 5 m SCD12xx...

Page 34: ...Page 34 optoCONTROL 1202 12 Factory Setting Mode L Edge Average number 2 values...

Page 35: ......

Page 36: ...trotec GmbH Manfred W rner Stra e 101 73037 G ppingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon de www micro epsilon com X9751200 A051069SWE X9751200 A05 MICRO EPS...