Page 51
Operation
MSC7401 / 7802 / 7602 Miniature sensor controller for inductive displacement sensors
D1:
Channel
D2:
E1
D4:
Value
Next menu
G
Adjustment
ENTER
R
2-point
adjustment
ENTER
Go to the adjustment modes
2-point adjustment
.
ENTER
E1 level
G
Factory settings
O
Zero-point search
G
MENU
(3 sec.)
Automatic
sensor reco-
gnition
ENTER
G
Successful
G
Successful
E1 level
R
R
Failed
R
Failed
Sensor parameter
G
Manually set
Manually set
Display only
O
Signal
ENTER
G
Automatic
ENTER
O
ENTER
E1 level
R
R
Current
O
Voltage
Voltage
G
0 ... 10 V
O
2 ... 10 V
R
0 ... 5 V
R
0.5 ... 4.5 V
R
Current
Current
G
4 ... 20 mA
O
0 ... 20 mA
R
0 ... 10 mA
D3:
E2