Page 36
Installation and Assembly
MSC7401 / 7802 / 7602 Miniature sensor controller for inductive displacement sensors
4.4.3
Sensor
The output signal increases, when the plunger is moved into the sensor. If the reverse effective direction is
required (i.e. the signal becomes smaller when the plunger is inserted), replace the connections sec+ and
sec-.
Pin assignment
Sensor 1 + 2
(DTA/LVDT)
Variant with cable gland
Sensor 1
Sensor 2
1
2
3
4
5
6
X2-1
1
2
3
4
5
6
X2-2
Connector
1
2
3
4
5
5-pin housing socket M9
(Binder, series 712)
View on pin side
Assignment
Pin X2-x
DTA-x-CA-x
DTA-x-CR-x
Cable C701-x
DTA-x-
CA-x
DTA-xG8-x 5-pin
Shield
1
Shield
-
Shield
Housing
Secondary center tap 2
Gray
Gray
Gray
5
Sec
3
White
White
Black
1
Secondary -
4
Brown
Black
White
2
P
5
Green
Green
Blue
3
Primary -
6
Yellow
Yellow
Brown
4
Fig. 30 Table for pin assignment of sensor (DTA/LVDT)