Installation and Assembly
MSC7401 / 7802 / 7602 Miniature sensor controller for inductive displacement sensors
4.5
Power Supply, Sensor and Signal Output
MSC7602
The MSC7602 is designed for multi-channel operation. Therefore, power supply and RS485 must therefore
be applied only to one controller and can then be transmitted to the adjacent controller via a DIN rail bus
connector on the rear side.
The Sync signal is only available on the DIN rail bus connector and executed in series, i.e., it is not dai-
sy-chained in the bus connector.
All of the connections for the power supply/sensors/signal output are on the controller
Connections:
Screw terminal connection; AWG 16 up to AWG 24; up to AWG 28 with ferrule
X1
X2-2
Connection
for
sensor 2
X3
X2-1
Connection
for
sensor 1
Din rail
bus connector
Fig. 32 View MSC7602
Fig. 33 Upper view,
MSC7602
Fig. 34 Lower view,
MSC7602
Fig. 35 View rear side,
MSC7602 inclusive
DIN rail bus connector