Page 45
Set Sensor Parameter
optoNCDT 1220
7.4.4
Triggering
7.4.4.1
General
The optoNCDT 1220 measurement output is controllable through an external trigger signal or a command.
Triggering affects the analog and digital output.
The measurement value at the time of triggering is output
.
- Triggering does not influence the timing so that between the trigger event (level change) and the start of
output always lie 3 1 cycle (Jitter).
- The multifunctional input is used as external trigger input, see Chap.
.
- Factory setting: no triggering, the sensor starts data transmission right after start-up.
- Pulse duration of the “Trigger in“ signal must be at least 50
µs.
Output
trigger
Level
A continuous measurement task is following as long as
the chosen level remains the same. Choice of level, see
Chap.
. Pulse duration must be at least a cycle time.
The following pause must be at least a cycle time..
Edge
infinite
Edge selection, see Chap.
“1 ... 16382“ values per trigger, “16383“ endless trigger
manual Number Value
Inactive
No triggering
Valid with triggering:
f
T
< f
M
f
T
Trigger frequency
f
M
Measuring rate