System Settings
7.6.1
General
After programming all the settings are to be stored permanently in a set of parameters. The next time you turn
on the sensor they are available again.
7.6.2
Unit, Language
The web interface promotes the units millimeter (mm) and inch when displaying measuring results.
You can choose German, English or Chinese in the web interface. You can change language in the menu bar.
Fig. 38 Language selection in the menu bar
7.6.3
Keylock
The function keylock for the key
prevents unauthorized / unintended performing
of the key functions. Keylock is always activated when user level
User
is chosen. Keylock can only be deacti-
vated in user level
Expert
. If an expert logs in the system, keylock on the sensor is automatically unlocked.
Key lock
Automatic
Range from 1 ... 60 [min]
Value
Keylock starts after expiry of defined time.
Clicking the button
Refresh
prolongs the
timeframe until keylock starts.
Active
The key
Select
is deactivated indepen-
dent of the user level.
Inactive
The key
Select
is active independent of
the user level.
Grey shaded
fields require a
selection.
Value
Dark-bordered
fields require you
to specify a value.