![Meyra Optimus 2 2.322 Service Manual Download Page 62](http://html1.mh-extra.com/html/meyra/optimus-2-2-322/optimus-2-2-322_service-manual_1782028062.webp)
62
REPLACEMENT OF THE OPERATING
MODULE
REMOVE THE OPERATING MODULE
– With the locking device bolt (A) depressed, swivel
the cable protection down (B).
– Press the plug latch (C) and pull the plug.
– Loosen the clamping screw (D) of the bracket and
pull the operating out toward the front.
– Mount the operating module off of the bracket.
FITTING OF THE OPERATING MODULE
– Mount the operating module to the bracket.
– Insert the operating module from the front into the
bracket, adjust to the desired position and tighten
the clamping screw (D).
– Insert the connector plug fort he operating module
(E).
– With the locking bolt (A) depressed, swivel the ca-
ble protection up (F), in doing so straighten the plug
and prevent it from being bent.
CHECKING THE CABLE LAYOUT
After replacing the operating module and during main-
tenance the correct layout of the cables of the supply
lines to the operating module is to be checked:
!
Attention:
a) The operating module must be able to swivel com-
pletely forward and backward without the cables
being pulled taught.
b) The cable may not exceed the contour of the ve-
hicle in operation setting.
A
B
C
D
A
F
E