51
SHK 200S
SHK 200S-6
Menu 5.1.6 - fan sp. supply air
Menu 5.1.12 - addition
Set the speed for the five different selectable speeds
for the fan here.
CAUTION
An incorrectly set value may damage the house
in the long term and possibly increase energy
consumption.
Chapter 9 |
Control
IMPORTANT
Menu 5.1.6 is inactive in the factory settings. For this
menu function to be active, the ERS accessory must be
installed and activated in the accessories menu. 5.2.4.
IMPORTANT
The factory settings introduced in menu 5.1.12 are the
required settings. Editing these settings is only possible
by authorized installers and service technicians!
The settings in this menu apply to the method of con-
trolling the auxiliary heater.
max step
Setting range (binary stepping deactivated): 0 – 3
Setting range (binary stepping activated): 0 – 7
Factory setting: 3
binary stepping
Setting range
: activee / inactive
Factory setting: binary stepping: inactive
Factory setting:
add. type: step controlled
Factory setting: positioning: before QN10
normal and speed 1-4
Setting range: 0 – 100 %
Factory setting: normal: 75%
Factory setting: speed 1: 0%
Factory setting: peed 2: 30%
Factory setting:speed 3: 80%
Factory setting: speed 4: 100%
fuse size
Setting range: 1 - 200 A
Factory setting:
20 A
transformation ratio
Setting range: 300 - 3000
Factory setting:
300
The type of heating distribution system the heating
medium pump works towards is set here.
dT at DOT is the difference in degrees between flow
and return temperatures at dimensioned outdoor
temperature.
Menu 5.1.14 - flow set. climate system
presettings
Setting range: radiator, floor heat., rad. + floor heat.,
DOT °C
Default value: radiator
Setting range DOT: -40,0 – 20,0°C
The factory setting of DOT value depends on the
country that has been given for the product's location.
The example below refers to Poland.
Factory setting DOT: -20.0 °C
own setting
Setting range dT at DOT: 0,0 – 25,0
Factory setting dT at DOT: 10,0
Setting range DOT: -40,0 – 20,0°C
Factory setting DOT: -20,0°C
Summary of Contents for SHK 200S
Page 2: ......
Page 70: ...70 SHK 200S SHK 200S 6 Diagram of electrical connections Chapter 13 Technical data...
Page 71: ...71 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 72: ...72 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 73: ...73 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 74: ...74 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 75: ...75 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 76: ...76 SHK 200S SHK 200S 6...
Page 77: ...77 SHK 200S SHK 200S 6...
Page 78: ...78 SHK 200S SHK 200S 6...
Page 79: ......
Page 80: ...METRO THERM A S RUNDINSVEJ 55 DK3200 HELSINGE INFO METROTHERM DK WWW METROTHERM DK 08 242 1909...