![Metro Therm SHK 200S Installation And Operating Manual Download Page 49](http://html1.mh-extra.com/html/metro-therm/shk-200s/shk-200s_installation-and-operating-manual_1779421049.webp)
49
SHK 200S
SHK 200S-6
Cooling settings
In the factory settings of the SHK 200S / SHK 200S-6
the cooling is activated, but it requires additional set-
tings to be activated.
To start the cooling, change the parameter "turn on
cooling" to the value above which (regarding out-
side temperature) the cooling should begin. set in
menu 1.9 (settings can be found in menu 1.9.1.2 and
1.9.3.2).
If the average temperature calculated by the "calcula-
tion time" is higher than the set temperature, cooling
according to set in menu 1.9 (settings can be found in
menu 1.9.1.2 and 1.9.3.2).
CAUTION
The settings for cooling should be made based on the
existing CH system.
The above cooling settings can only be edited by qual-
ified personnel.
Factory setting:
IMPORTANT
Incorrect settings in the service menus can damage the
installation, heat pump and indoor unit.
Submenu SERVICE
Menu 5.1 - operating settings
Menu 5.1.1 - hot water settings
Menu
SERVICE
has orange text and is intended for
the advanced user. This menu has several sub-men-
us. Status information for the relevant menu can be
found on the display to the right of the menus
• operating settings
Operating settings for the
control module.
• system settings
System settings for the control
module, activating accessories etc
• accessory settings
Operational settings for dif
-
ferent accessories.
• soft in/outputs
Setting software controlled in
and outputs on the input card (AA3) and terminal
block (X2).
• factory setting service
Total reset of all settings
(including settings available to the user ) to de-
fault values.
• forced control
Forced control of the different
components in the indoor module
• start guide
Manual start of the start guide which
is run the first time when the control module is
started.
• quick start
Quick starting the compressor.
Go to the main menu and hold the Back button in for 7
seconds to access the Service menu.
Operating settings can be made for the control mod
-
ule in the sub menus.
Operating settings can be made for the control mod
-
ule in the sub menus.
economy
Setting range start temp. economy: 5 – 55°C
Factory setting start temp. economy: 39°C
Setting range stop temp. economy: 5 – 60°C
Factory setting stop temp. economy: 43°C
normal
Setting range start temp. normal: 5 – 60°C
Factory setting start temp. normal: 42°C
Setting range stop temp. normal: 5 – 65°C
Factory setting stop temp. normal: 46°C
luxury
Setting range start temp. lux: 5 – 70°C
Factory setting start temp. lux: 45°C
Setting range stop temp. lux: 5 – 70°C
Factory setting stop temp. lux: 49°C
Summary of Contents for SHK 200S
Page 2: ......
Page 70: ...70 SHK 200S SHK 200S 6 Diagram of electrical connections Chapter 13 Technical data...
Page 71: ...71 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 72: ...72 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 73: ...73 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 74: ...74 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 75: ...75 SHK 200S SHK 200S 6 Chapter 13 Technical data...
Page 76: ...76 SHK 200S SHK 200S 6...
Page 77: ...77 SHK 200S SHK 200S 6...
Page 78: ...78 SHK 200S SHK 200S 6...
Page 79: ......
Page 80: ...METRO THERM A S RUNDINSVEJ 55 DK3200 HELSINGE INFO METROTHERM DK WWW METROTHERM DK 08 242 1909...