5.1 Troubleshooting
When incurring any problem with the Flamespray process, it is necessary to first check that
the correct consumable parts i.e. Nozzle Assembly, are fitted and in good condition.
Spraying parameters should also be checked as per
Section 8: Flowmeter Settings
.
If the problem still persists, then consult the below tables. These are the most commonly
occurring problems, their causes and the action that should be taken to rectify the problem.
PROBLEM
CAUSE
REMEDY
Pistol
Does
Not Light
Valve opened too quickly
Open Valve less quickly
Spring Washer is weak, missing or damaged
Replace Spring Washer (1024)
Nozzle Assembly parts worn, dirty or damaged
Replace and insert parts
Incorrect Nozzle Assembly
Replace with correct parts
Wire protruding too far forward from Nozzle
Pull wire back until flush with Nozzle front
face
PROBLEM
CAUSE
REMEDY
Pistol
Backfires
Leaks in Nozzle Assembly
Inspect ‘O’ Rings for damage or loss and
tighten Air Cover
Oversize gas holes in Nozzle Shell
Replace Nozzle Shell
Incorrect Pressures
Check that air, gas and oxygen pressures
are as recommended in Section…
Incorrect Nozzle parts
Check part numbers (Section 7)
Restrictions in Oxygen/Gas holes in Mixing
Block
Check oxygen and gas ports and clean as
necessary
Debris in Air Nipple
Carefully clean Air Nipple
Valve opened too quickly
Open Valve less quickly
Wire protruding too far forward from Nozzle
Pull wire back until flush with Nozzle face
Wire feeding too fast
Slow down wire speed
Summary of Contents for MK 73
Page 1: ...Page 1 of 64 ssue 21 11 11 ...
Page 43: ...Page 43 of 64 SECTION 5 FAULT FINDING 5 1 Troubleshooting 5 1 2 Flowmeter Troubleshooting ...
Page 58: ...Page 58 of 64 SECTION 8 INFORMATION TABLES 8 1 Flowmeter Settings 8 2 Nozzle Selection Chart ...
Page 61: ...Page 61 of 64 Notes ...
Page 62: ...Page 62 of 64 ...
Page 63: ...Page 63 of 64 ...