FLUX 0
50 L
FLUX 0
200 L
Measured flow range
Nl/min
0 - 50
0 - 200
Direction of flow
Unidirectional
Working pressure range
bar
-0.9 to 8
MPa
-0.09 to 0.8
psi
-13 to 116
Maximum admissible pressure
bar
10
Pipe diameter for push-in fitting
mm
8
Connecting cable
VDC
12 to 24 ± 10%, ripple max 10%
Current consumption
mA
≤ 50
Power cable
Cable Ø 4 length 2 m, oil resistant, 26 AGW (6 x 0.15 mm
2
)
Weight
g
100 (including cable)
DISPLAY
lnstant flow rate
Display range
Nl/min
0 - 50
0 - 200
Minimum setting scale
Nl/min
0.1
1
ft
3
/min
1
1
Cumulative flow rate
Display range
9999999.9
99999999
Minimum setting scale
Nl
0.1
1
ft
3
1
1
Pressure
Display range
kPa
-100 to 1000
Minimum setting scale
kPa
1
bar
0.01
psi
0.1
PRECISION
Flow rate
Guaranteed measuring range
2 to 100 % FS
Display accuracy
± 3 % FS ± 1 digit
s
Analogue output accuracy
± 5 % FS
s
Repeatability
± 1 % FS ± 1 digit
n
Linearity
± 3 % FS
n
Temperature characteristic
± 2 % FS for a temperature range of 15-35°C; ± 5 % FS for a temperature range of 0-15°C or 35-50°C
n
Pressure characteristic
± 5 % FS ± 1 digit
✱
Pressure
Guaranteed measuring range
0 to 100 % FS
Display accuracy
± 2 % FS ± 1 digit
●
Analogue output accuracy
± 2.5 % FS
●
Repeatability
± 0.2 % FS ± 1 digit
●
Linearity
± 1 % FS
●
Temperature characteristic
± 2 % FS
●
DIGITAL OUTPUTS
N ° outputs
2 PNP
Max current
mA
125
Max voltage
VDC
24
Residual voltage
V
≤ 1.5 V
Response time, with flow rate setting
ms
50, 80, 120, 200, 400, 800, 1500 (default 800)
Response time, with pressure setting
ms
2.5, 25, 100, 250, 500, 1000, 1500 (default 2.5)
Response mode, with flow rate setting
Hysteresis mode, window comparison mode, cumulative mode, cumulative pulse mode
Normally open or normally closed
Response mode, with pressure mode setting
One-point setting mode, hysteresis mode, window comparison mode. Normally open or normally closed
Hysteresis
Adjustable
Short-circuit protection at output
Yes
Cumulative pulse output
Nl/impulse
0.5
2
ft
3
/impulse
2
7
s
Data valid under these conditions: input pressure 3 bar, output pressure 1 bar, temperature 25°C
n
Data valid under these conditions: output pressure 1 bar, temperature 25°C
✱
Data valid under these conditions: -90 to 800 kPa, output pressure 1 bar, temperature 25°C
●
Data valid under these conditions: flow rate 0 Nl/min, temperature 25°C
4. TECHNICAL DATA