1. INSTALLATION
@2019 KITA Sensor Tech. Co., LTD. URL hiip://www.kita.com.tw
-5-
Installation
K F P 0 1
Series
Instruction Manual
1
Installation
1.1 Piping
Install the pipe by following the arrow indication that shows the air flow
direction on the product.
Blow the air to flush out the foreign matters,
dust and etc. before installing the pipe.
Uncleaned air may cause malfunction or
damage to the product.
Piping for the One-Touch Fitting, insert the
tube firmly into the fitting and make sure it
cannot be pulled out.
Also using the proper tube cutter is
recommended to ensure square
edge tube.
Flow direction
Use straight piping 8cm or longer to connect the Piping Port (Inlet side).
If straight piping is not installed, the accuracy may vary by ± 2% F.S..
※
Straight Piping: The pipe is without bending and the cross sectional areas of the
pipe keeps the same.
Piping Port
(Inlet side)
straight piping 8cm
or longer
Piping Port
(Outlet side)