K F P 0 1
Series
Instruction Manual
How to Use
Fixed Hysteresis
Mode
NO mode
NC mode
Ag
kPa
L /min
Selected
Output
Selected
Mode
Output Type Setting
OUT1 type setting :
Press or button to select OUT1
type.
Ag
kPa
L /min
Ag
kPa
L /min
※
NOTE
:
Type setting will not display when Accumulated Pulse Output Mode is set.
Ag
kPa
L /min
Set Value
Selected
Mode
Set Value Setting
Out1 set value setting :
Press or button to adjust the set
value.
Hysteresis Mode
[
HYS
]
:
[
FL-1
],[
FH-1
]
Window Comparator Mode
:
[
FL-1
],[
FH-1
]
Accumlated Output Mode
[
ADD
]
:
[
AddL
],[
AddH
]
※
NOTE
:
Set value setting will not display when Accumulated Pulse Output is set.
Ag
kPa
L /min
Set Value
Fixed Hysteresis Setting
Fixed hysteresis setting :
Press or button to adjust fixed
hysteresis value.
※
NOTE
:
Fixed hysteresis setting will not display when Hysteresis Mode, Accumulated Output Mode and
Accumulated Pulse Output Mode is set.
Ag
kPa
L /min
Press button
Press button
Press button to return to
Function Selection Mode