2.2 Function Instruction
●
Function Setting Mode
●
Measurement Mode
Item
Explanation
[ F-01 ]
[ F-02 ]
[ F-03 ]
[ F-04 ]
[ F-05 ]
[ F-06 ]
[ F-08 ]
[ F-09 ]
[ F-10 ]
[ F-91 ]
[ F-92 ]
[ F-94 ]
[ F-95 ]
[ F-99 ]
[oUt1 ]
OUT 1 setting
[oUt2 ]
OUT 2 setting
[CLor ]
LCD Display color selection
[rESP]
Response time selection
[UPdA
]
Display refresh time selection
[Unit ]
Unit selection
[rEFE]
Flow reference standard
selection
[ AnG
]
Analog output selection
[EEPr]
Accumulated value hold
selection
[ diS ]
Flow sensor display mode
selection
[ ECo
]
Power-Save mode selection
[ inP ]
External input selection
[FinE ]
Fine adjustment Setting
[FoUt ]
Forced output function
[rESt ]
Reset to the default setting
Select Output 1 corresponding to flow sensor or
pressure sensor. Set the flow rate or pressure
value to switch ON/OFF.
Select Output 2 corresponding to flow sensor or
pressure sensor. Set the flow rate or pressure
value to switch ON/OFF.
Select back light color and display mode.
Select the response time for analog output.
Pressure sensor: 2.5ms ~ 1500ms.
Flow sensor: 50ms ~ 1500ms.
Display refresh cycle can be set in 200ms, 500ms
or 1000ms.
Select the UNIT of pressure / flow sensor.
Select the flow value is shown under standard (ANR)
or normal condition (NOR).
Select the analog corresponding to pressure or flow
sensor.
To save the last accumulated flow value every 2 or
5 minutes.
Select to display Instantaneous Flow or Accumulated
Flow Mode.
Select if turn on power-save mode to reduce power
consumption
Select for Accumulated flow rate zero clear,
Auto-Shift or Auto-Shift zero.
The displayed value can be adjusted slightly.
To turn the analog ON/OFF forcibly.
Return to the factory default setting.
[ F-07 ]
Function
Code
Item
Explanation
Pressure display
Flow display
Accumulated flow rate display
Pressure zero setting
Instantaneous Flow rate zero setting
Accumulated flow rate zero clear
Peak value display
Bottom value display
Key lock/unlock mode
Display pressure value.
Display instantaneous flow rate.
Display accumulated flow rate.
The displayed pressure value can be adjusted to "0".
The displayed instantaneous flow rate value can be adjusted to "0".
The accumulated flow rate can be set to "0".
The maximum pressure or instantaneous flow can be detected when
the power is supplied for a period.
The minimum pressure or instantaneous flow can be detected when
the power is supplied for a period.
To prevent errors occurring due to unintentional changes of the set values.