2.3.12
[
F-92
]
External Input Selection
Accumulated flow external reset
:
The accumulated flow value will
reset to "0" when an external input signal is applied.
Auto-shift
:
The instantaneous flow rate will regard as the standard
when the external input signal is applied. The switch output
function operates relative to its change.
Auto-shift zero
:
The instantaneous flow rate is reset to zero to regard
as standard when the external input signal is applied.
The switch output function operates relative to its
change.
This function is only for output 1 corresponding to flow sensor action point.
When external signal is input, please connect the input wire to GND for
30 ms or more.
<
Operation >
Press or button at Function Selection Mode to display
[
F-92
] [
inP
]。
External Input Selection
Press or button to select external
input function.
Ag
kPa
L /min
Ag
kPa
L /min
Ag
kPa
L /min
Ag
kPa
L /min
Ag
kPa
L /min
Ag
kPa
L /min
External
Input
Selected
Mode
※
NOTE
:
1. Output specification 02 and 04 have no this function.
2. When external signal is input, the instantaneous flow
rate value will be shown ”
oooo
”.
Accumulated flow external reset
Auto-shift
Auto-shift zero
Press button
Press button to return to
Function Selection Mode