45
8.10
Parameter series 8, maintenance settings
Parameter Description
Settings
8.5
Number of cycles before
maintenance
(per 1,000 cycles, setting
possible from 1,000 (= 1)
to 99,000 (= 99))
1 to 99
8.7
Maintenance counter
.1) Deactivated.
X
.2)
Activated;
(message and close door when counter reaches 0)
.3) Activated;
(message when counter reaches 0)
8.9
Display maintenance cycle
counter
Maintenance cycle counter is displayed.
This counts down to 0 from the configured value.
Upon reaching 0, a message is sent to perform
maintenance.
8.11
Parameter series 9, registration
Parameter Description
Settings
9.1
Cycle counter
Number of times door has opened.
(cannot be reset)
9.2
Last 20 error messages.
The last 20 error messages are displayed from the
newest to the oldest. Interrupt display by pressing
“menu stop/ok” button.
9.3
Number of cycles after
programming changes
The number of cycles are displayed since the last
change in the menu.
9.4
Software version
Software version is displayed.
9.5
Reset to factory settings
.0) Do not perform reset and return to the menu.
.1) Perform reset, restart controller (press “menu
stop/ok” button for 5 sec. to confirm.)