25
7.1
Commissioning
The end switches of the drive unit must first be connected before power is switched on for the first
time. The controller will then automatically recognize the used end switches when switched on, and
the controller will configure accordingly. It is not possible to move the door if the controller is not
configured correctly. If this is the case, the controller can be easily modified or reset.
The controller can only be configured effectively via the menu once the end positions have been set.
7.2
Configuring end switches (NES)
Table 8 Configuring end switches (NES)
Start programming: Check operating direction
Change direction of rotation, if necessary
Move to OPEN final limit position and adjust S3 OPEN limit switch
Move to CLOSE final limit position 5 cm above the ground and adjust S5 pre-limit switch
Move to CLOSE final limit position and adjust S4 CLOSE limit switch