4.7.5
Mount AP433e on a Dropped Ceiling Bevel Tile
The mounting procedure for a ceiling that has recessed supports and lowered tiles
is similar to that of mounting on a suspended ceiling. However, this procedure
requires a specialized mounting bracket, as shown in Figure 13, Dropped Bevel
Tile Mounting Adapter (MNT-SCRMKIT-03)
Figure 13, Dropped Bevel Tile Mounting Adapter (MNT-SCRMKIT-03)
•
Remove the ceiling tile alongside which the AP will be mounted.
•
Be sure that AP433e is not locked by inserting the locking key into the
Unlock mechanism as
•
Align the mounting bracket with the AP433e slots used for the ceiling t-
bar in Mount AP433e below Suspended Ceiling.
•
Press down on the tab indicated on the underside of the AP and twist the
AP into place.
•
Push down on the thumbscrews provided on the mounting bracket and
clip it to the ceiling bar that will support the AP.
•
Tighten the screws to ensure that the mechanism stays locked in place.
•
Connect one end of the CAT5 (or greater) Ethernet cable with PoE to the
Ethernet connector shown in Figure 15 above.
Caution!
Be sure to connect the Ethernet cable to the Ethernet port. The cable can
mistakenly be plugged into the Console port; if you do this, the AP won’t power up.