4-17
Routine Service and Maintenance
6. Check battery signs of leakage or for corrosion on the battery cables.
• On a monthly basis, check the battery (Item 1,
) for signs of leaking electro-
lyte. If any signs of damage are visible, remove and replace the battery.
Wear the proper protective clothing when handling the battery. Leaking battery fluid
contains acid that can cause burns. Fumes from the leaking fluid can cause respiratory
problems.
• Check both of the battery cables (Items 2 and 3,
) for signs of damage or cor-
rosion. Loosen the cable clamps and remove the cable from the battery. Clean the termi-
nals with a battery brush. Reinstall and secure the cable clamps.
NOTE:
To prevent corrosion, spray on a battery protectent and sealer onto both terminals
and cable clamps after cables are installed..
• Check the battery hold down clamp (Item 5,
) to make sure that the battery is
being held securely to the machine.
Figure 4–19 Battery and Connections
CAUTION
5
4
3
2
1