V5
75
5-
58
1-
02
0
1/1
5
7
Example of blind control:
Set -32 minutes for the location Cologne. This has the
consequence that the blinds are lowered in accordance
with the later sunset time (32 minutes later than Görlitz).
Random function
This enables you to give any external observer the im-
pression that you are at home. The random function uses
an integrated random generator to vary the times you set
by between 0 minutes and 30 minutes every day.
A
Set UP time 7:30 a.m.
B
Set DOWN time 6:30 p.m.
C
Random range 0-30 minutes
You can activate the random function separately for each
switching time (see "Set switching times").
Additional functions for blind control
Individual blind movement time
The module is preset at the factory so that the blind takes
2 min. to be lowered (and, where necessary, stops auto-
matically when the lower limit position is reached). You
can adjust this time freely between 30 seconds and 3
minutes. This means scenes can be performed faster.
(see "Setting individual blind movement time").
Sun protection function
The sun protection function is activated as soon as the
brightness at the window measured by the sun/twilight
sensor exceeds the set limit value for 2 minutes. The
blind is lowered to below the sensor and moves back up
again for the movement time set. The time the blind
moves back up needs to be set so that the blind stops
just above the sensor. If the measured brightness falls
below the limit value for 15 minutes, the blind is raised
again.
The brightness limit value and the raising time can be set
in the advanced menu of the module (see "Setting the
brightness threshold for sun protection function" and
"Setting the blind position for sun protection function").
1. The sun/twilight sensor measures the brightness. The
limit value is exceeded.
2. The blind is lowered. The sensor is now in the shade,
the blind stops below the sensor.
3. Blind is raised for the duration set and stops above the
sensor.
|
Manual operation of the module deactivates the
sun protection function. The sun symbol is not
visible on the display.
The sun protection function is only active when
the blind is completely raised.
18.00
0
7.00
8.00
19.00
0...30 min
0...30 min
A
B
C
C
2
1
3
Disabling blind movement with magnetic contact
(Only in combination with blind control insert, brightness
sensor interface flush-mounted and magnetic contact)
Raising/lowering the blind via PlusLink commands or via
switching times of the display timer module is disabled
by a magnetic contact when the window or door is open.
Manual operation is still possible with the and push-
buttons.
A
Magnetic contact
½
CAUTION
Risk of burglary!
Please bear in mind that the blind will not close
while the window/door is open when using the
magnetic contact.
Wind alarm
In order to protect blinds or awnings from damage
caused by strong wind, you can set a blind behaviour for
wind alarm.
As soon as the wind speed set on the wind sensor has
been steadily exceeded for a period of at least 15 sec-
onds, the blind reacts according to the set behaviour
(see "Setting the behaviour for wind alarm"). There are
three possible settings:
• Blind is lowered in the event of wind alarm (standard
setting).
• Blind is raised in the event of wind alarm.
• Blind does not react to wind alarm.
During this time and until the wind speed drops, lowering
and raising the blind via PL or module switching times is
disabled. Manual operation is still possible with the
and push-buttons. The blind is not automatically low-
ered or raised after the wind alarm is over.
1. Blind is partially lowered.
2. The wind is increasing and exceeds the limit value. Af-
ter 15 s the sensor interface triggers a wind alarm via
the PL.
3. The blind behaves according to its settings.
Evaluating DCF timer
(Only in combination with brightness sensor with wind
sensor interface and DCF)
The module can receive a DCF time signal via a sensor
interface connected to the PlusLink. The DCF time sig-
nal is sent to the module via PL once a day (approx. at 2
o'clock in the morning). The module uses this to auto-
matically set the current date and time.
With the DCF time signal the changeover from summer
to winter time occurs automatically.
Response to mains voltage failure and
recovery / power reserve
In the event of mains voltage failure the display goes out.
The following menu settings are saved permanently:
• Switching times
• Arrow button function
• Scenes
• Blind position for the sun protection function
• Display settings
• Operating mode
Menu
OK
Man
A
1
3
2
15 s
The set time and date are saved for at least 6 hours
thanks to the power reserve (no batteries required).
After mains voltage recovery the next switching time is
carried out. Missed switching times are not carried out.
Deactivate the time and PlusLink control
Press the
[Man]
push-button to switch the module to
manual mode and deactivate the control via set switch-
ing times and via PlusLink commands. Loads can then
only be controlled manually with the and push-but-
tons.
|
Exceptions:
• The panic scene is being executed.
• In combination with a blind control insert, the
module reacts to sensor values via PlusLink
and controls the blind accordingly.
To switch back, press the
[Man]
push-button for 2 s.
After switching to manual mode, "Auto" disappears from
the display and the LED next to the
[Man]
push-button
lights up red.
Basic functions
Status LEDs for the module
Resetting to default settings
Operating the module
Operation
Status feedback
– green LED briefly
lights up upon ac-
tuation
– Arrow symbol ap-
pears when load
is activated (light
on / blind is
raised)
– green LED briefly
lights up upon ac-
tuation
– Arrow symbol ap-
pears when load
is activated (blind
is lowered)
Operation
Status feedback
all LEDs briefly flash
red and all display
symbols appear
2 s
Menu
OK
Man
Menu
OK
Man
Menu
OK
Man
10 s
Menu
OK
Man