background image

V5

75

5-

58

1-

02

 0

1/1

5

8

Controlling blinds

• raising/lowering (> 0.5 s)
• up/down in steps (< 0.5 s)

Global blind control

|

Global control via PlusLink is possible in combi-

nation with the central unit insert and the display 

timer module.

Example of global raising/lowering and gradual up/

down of 1-4 PL lines

Following activation of the push-buttons   and   of the 

module on the central unit insert, all loads in the PL lines 

are controlled together.

Arrow buttons with push-button function:

• Long push-button action (> 0.5 s): raising/lowering
• Short push-button action (< 0.5 s): up/down gradually

A

Module on central unit insert

B

Blind control insert

Switching load on/off

In combination with 1-gang / 2-gang insert

|

In combination with a 2-gang insert both channels 

are switched together.
Display of the status arrow in the display only re-

fers to channel 1.

Blind control

Light control

<  0,5 s

> 0,5 s  

<  0,5 s

> 0,5 s

Menu

OK

Man

A

B

B

PL4 PL3 PL2

PL1

<  0,5 s

> 0,5 s  

<  0,5 s

> 0,5 s

Menu

OK

Man

<  0,5 s

Menu

OK

Man

Dimming load

In combination with 1-gang / 2-gang insert

|

In combination with a 2-gang insert both channels 

are dimmed together.
Display of the status arrow only refers to channel 

1.

Global light control

|

Global control via PlusLink is possible in combi-

nation with the central unit insert and the display 

timer module.

Example of globally switching on/off and dimming 

the 1-4 PL lines

Following activation of the push-buttons   and   of the 

module on the central unit insert, all loads in the PL lines 

are controlled together:

Arrow buttons with push-button function

• Short push-button action (< 0.5 s): turn on/off
• Long push-button action (> 0.5 s): dimming

A

Module on central unit insert

B

Inserts for switching and dimming (see function 

overview)

|

Global scenes are possible via the arrow buttons 

in combination with the central unit insert and the 

display timer module (from version 1.5).

Arrow buttons with scene function:

• Short push-button action (< 0.5 s): Retrieve scene 1/2

Global blind and light scenes

Retrieve scene 1

Retrieve scene 2

> 0,5 s

Menu

OK

Man

A

B

B

B

PL4 PL3 PL2

PL1

<  0,5 s
<  0,5 s

> 0,5 s  

> 0,5 s  

Menu

OK

Man

<  0,5 s

Menu

OK

Man

• Central unit insert or side controller Plus, 1-gang/2-

gang:
switching, dimming, controlling blinds and retrieving 

scenes

• Mechanical push-button/double push-button
• Sensor int sensors

"FAIL" flashes on the display, all LEDs flash red.

• Module was plugged onto an insert that differs in func-

tionality from the previous one.
– Reset module to default settings.

The blind or lighting does not react to a set switch-

ing time.

• PlusLink commands deactivate the switching times.

– The panic scene is being executed.
– Wind alarm is active.
– Window / door with magnetic contact is open.
– Sun/twilight sensor is performing sun protection 

function.

– All other PlusLink commands and switching times 

are performed when levels 1 - 4 are not carried out.

• The module is in manual mode. 

While the astro function is activated, the blind and 

the lighting activities deviate significantly from the 

actual times of sunrise or sunset.

• Date/time settings and astro time shift are not set cor-

rectly.

• Switching between summer/winter time is not activat-

ed. 

The sun protection function is not performed.

• The brightness threshold is set too high.

– Reduce brightness threshold in advanced menu.

• Blind is not in the top limit position. Any manual actua-

tion deactivates the sun protection function.
– Bring blind into top position with a long push of the 

button and wait for max. 2 min. (running time).

• Wind alarm is active and disables lowering of the 

blind. The wind symbol is shown on the display.
– Await wind alarm.

• The sun/twilight sensor is in the shade and cannot de-

tect sunlight.
– Install sun/twilight sensor on the window in such a 

way that sunlight is reliably detected.

– Raise the blind position for the sun protection func-

tion in the advanced menu.

• The window / door is open. The magnetic contact dis-

ables lowering of the blind.
– Close window / door.

• The panic scene is being executed.
• The module is in manual mode.

When the window / door with magnetic contact is 

open, the blind moves up or down.

• Wind alarm is active, causing the blind to be raised to 

top position.
– Await wind alarm.
– Change the blind's behaviour for wind alarm in the 

menu.

Controlling loads from another location 

via PlusLink

What should I do if there is a problem?

Summary of Contents for MEG5755-03 series

Page 1: ...witchover Individually adjustable blind movement time Adjustable brightness threshold for sun protection function Adjustable response for wind alarm Adjustable display brightness Automatic deactivation of display lighting can be se lected from version 1 5 Power reserve of at least 6 hours in the event of a pow er failure Reset restore default settings Table of Content Getting to know the display t...

Page 2: ...g the time Setting the day month and year Switching time 2 Sun protection function activated Setting the brightness threshold Wind alarm is executed Setting the behaviour for wind alarm Switching between summer and winter time DCF timer is evaluated Mounting the module B C A Initialising the module After plugging the module onto the insert for the first time information on the module type and modu...

Page 3: ...ion for sun protection function Set response for wind alarm Set display brightness Set automatic deactivation of display lighting The following push buttons are used to operate the menu With a long press of Menu the menu for setting the time and switching time appears after 2 s To open the advanced menu hold the Menu push button down If you do not press any push button in the menu for more than 2 ...

Page 4: ...sh button or 7 Confirm setting with OK The time display flashes 8 Set switching time with or push button 9 Confirm setting with OK The operating mode display flashes 0 Select operating mode with or push button and confirm with OK The time display flashes Set second switching time with or push but ton Confirm setting with OK If you press the Man push button a switching time set previously appears T...

Page 5: ...1 display appears 3 Confirm setting with OK The no display appears 4 Select save option yes with push button or 5 Confirm setting with OK Light scene All lamps are switched off briefly and then back on again to indicate that the saving procedure has been successful Then the lamps adopt the saved brightness value Blind scene The blinds are lowered and raised by one step to indicate that the saving ...

Page 6: ...astro function separately for each switching time see Set switching times If the activated astro function has calculated that it will still be dark outside at the set switching time e g Raise blind at 6 30 a m it will not raise the blind until the sun rises Likewise the blind will be lowered at sunset if the acti vated astro function has calculated that it will be dark be fore the set switching ti...

Page 7: ...damage caused by strong wind you can set a blind behaviour for wind alarm As soon as the wind speed set on the wind sensor has been steadily exceeded for a period of at least 15 sec onds the blind reacts according to the set behaviour see Setting the behaviour for wind alarm There are three possible settings Blind is lowered in the event of wind alarm standard setting Blind is raised in the event ...

Page 8: ...L2 PL1 0 5 s 0 5 s 0 5 s 0 5 s Menu OK Man 0 5 s Menu OK Man Central unit insert or side controller Plus 1 gang 2 gang switching dimming controlling blinds and retrieving scenes Mechanical push button double push button Sensor interface sensors FAIL flashes on the display all LEDs flash red Module was plugged onto an insert that differs in func tionality from the previous one Reset module to defau...

Page 9: ...per PL line 2 switching cycles day Functions Drift 1 s day Power reserve 6 hours no battery required Connectable ran dom generator 0 30 minutes Astro function Astro time shift 2 hours Standard blind movement time 2 minutes Display elements 5 LED LCD display Operating elements Menu push button Manual push button OK push button arrow push button UP arrow push button DOWN Connection module interface ...

Reviews: