Display timer moduleArt. no. MEG5755-03../-04..© Schneider-Electric 2014V5755-581-0201/15

– Complete the display timer module with: 
• Corresponding inserts (see function overview)
• Frame in design System M

¼

DANGER 
Risk of serious damage to property and per-

sonal injury, e.g. from fire or electric shock, 

due to incorrect electrical installation.

Safe electrical installation can only be ensured if 

the person in question can prove basic knowl-

edge in the following areas:
• Connecting to installation networks
• Connecting several electrical devices
• Laying electric cables
These skills and experience are normally only 

possessed by skilled professionals who are 

trained in the field of electrical installation technol-

ogy. If these minimum requirements are not met 

or are disregarded in any way, you will be solely li-

able for any damage to property or personal inju-

ry.

|

From version 1.5 the following functions are avail-

able:
• Two global scenes can be retrieved via push-

buttons

• Automatic deactivation of display lighting can 

be selected

After plugging the module onto the insert for the first 

time, information on the module type and module version 

are displayed for one second each.

Display timer module

Operating instructions

Art. no. MEG5755-03../-04..

Necessary accessories

For your safety

Module version

en

In combination with different inserts, you can carry out 

various functions with the display timer module (referred 

to below as 

module

), such as: 

• switching, dimming and controlling blinds manually
• time-controlled switching and controlling of blinds

Product features:

• Simple operation using five push-buttons
• Adjustable date and time
• Number of switching cycles (switching on/off, raising/

lowering):

Switching, dimming, blind inserts:

per channel: 2 switching cycles/day

Central unit insert:

per PL line: 2 switching cycles/day

• Switching times preset at the factory, but can be 

changed later

• Switching to manual mode possible
• Global control (max. 4 PL lines) and separate line con-

trol

• Saving scenes is possible
• Two global scenes can be retrieved via push-buttons

(from version 1.5)

• Astro function (control by astronomical pre-calculation 

of sunrise and sunset)

• Adaptation of astro function using specific astro time 

shift

• Random function ranging from 0-30 minutes
• Evaluating DCF timer
• Automatic summer/winter time switchover
• Individually adjustable blind movement time
• Adjustable brightness threshold for sun protection 

function

• Adjustable response for wind alarm
• Adjustable display brightness
• Automatic deactivation of display lighting can be se-

lected (from version 1.5)

• Power reserve of at least 6 hours in the event of a pow-

er failure

• Reset (restore default settings)

Table of Content

Getting to know the display timer module

1

Connections, displays and operating elements

2

Mounting the module

2

Getting to know the basic functions

3

Getting to know the menu

3

Setting module: Basic menu settings

3

Setting module: Advanced menu

4

Notes on advanced functions

6

Operating the module

7

Blind control

8

Light control

8

Global blind and light scenes

8

Controlling loads from another location via PlusLink 8
What should I do if there is a problem?

8

Technical data 

9

Getting to know the display timer 

module

Overview of module functions on re-

ceiving inserts

Complete the module with the receiving inserts for 

switching, dimming or controlling blind/roller shutter in 

order to carry out 

local

 light and blind control.

Function overview of the module on 

sending insert

Complete the module with the sending central unit insert 

in order to carry out 

global

 light and blind control via the 

PlusLink (PL)

.

Switching:

• Electronic 

switch insert

• Relay switch in-

sert

• switching on/off manually
• time-controlled switching on/off
• evaluating DCF timer

• Electronic 

switch insert, 2-

gang

• Relay switch in-

sert, 2-gang

• manually switching on/off both 

channels together

• time-controlled switching on/off of 

both channels separately or to-

gether

• evaluating DCF timer

Dimming:

• Universal  dim-

mer insert

• Control insert 

1-10 V

• DALI  insert

• switching and dimming manually
• time-controlled switching
• evaluating DCF timer

• Universal  dim-

mer insert, 2-

gang

• manually switching and dimming 

both channels at the same time

• time-controlled switching of both 

channels separately or together

• evaluating DCF timer

Controlling blinds/roller shutter:

• Blind control in-

sert

• raising/lowering manually
• time-controlled raising/lowering
• Sun protection function
• Wind alarm function
• disabling blind movement (with 

magnetic contact)

• evaluating DCF timer

Global light and blind control:

• Central unit in-

sert

• manual control for all PL lines to-

gether:

switching, dimming, lowering/

raising (push-button function) or 

retrieving scenes (scene function 

from version 1.5)

• time-controlled for all PL lines to-

gether or each PL line separately:

switching, raising/lowering

• evaluating DCF timer

Summary of Contents for MEG5755-03 series

Page 1: ...witchover Individually adjustable blind movement time Adjustable brightness threshold for sun protection function Adjustable response for wind alarm Adjustable display brightness Automatic deactivation of display lighting can be se lected from version 1 5 Power reserve of at least 6 hours in the event of a pow er failure Reset restore default settings Table of Content Getting to know the display t...

Page 2: ...g the time Setting the day month and year Switching time 2 Sun protection function activated Setting the brightness threshold Wind alarm is executed Setting the behaviour for wind alarm Switching between summer and winter time DCF timer is evaluated Mounting the module B C A Initialising the module After plugging the module onto the insert for the first time information on the module type and modu...

Page 3: ...ion for sun protection function Set response for wind alarm Set display brightness Set automatic deactivation of display lighting The following push buttons are used to operate the menu With a long press of Menu the menu for setting the time and switching time appears after 2 s To open the advanced menu hold the Menu push button down If you do not press any push button in the menu for more than 2 ...

Page 4: ...sh button or 7 Confirm setting with OK The time display flashes 8 Set switching time with or push button 9 Confirm setting with OK The operating mode display flashes 0 Select operating mode with or push button and confirm with OK The time display flashes Set second switching time with or push but ton Confirm setting with OK If you press the Man push button a switching time set previously appears T...

Page 5: ...1 display appears 3 Confirm setting with OK The no display appears 4 Select save option yes with push button or 5 Confirm setting with OK Light scene All lamps are switched off briefly and then back on again to indicate that the saving procedure has been successful Then the lamps adopt the saved brightness value Blind scene The blinds are lowered and raised by one step to indicate that the saving ...

Page 6: ...astro function separately for each switching time see Set switching times If the activated astro function has calculated that it will still be dark outside at the set switching time e g Raise blind at 6 30 a m it will not raise the blind until the sun rises Likewise the blind will be lowered at sunset if the acti vated astro function has calculated that it will be dark be fore the set switching ti...

Page 7: ...damage caused by strong wind you can set a blind behaviour for wind alarm As soon as the wind speed set on the wind sensor has been steadily exceeded for a period of at least 15 sec onds the blind reacts according to the set behaviour see Setting the behaviour for wind alarm There are three possible settings Blind is lowered in the event of wind alarm standard setting Blind is raised in the event ...

Page 8: ...L2 PL1 0 5 s 0 5 s 0 5 s 0 5 s Menu OK Man 0 5 s Menu OK Man Central unit insert or side controller Plus 1 gang 2 gang switching dimming controlling blinds and retrieving scenes Mechanical push button double push button Sensor interface sensors FAIL flashes on the display all LEDs flash red Module was plugged onto an insert that differs in func tionality from the previous one Reset module to defau...

Page 9: ...per PL line 2 switching cycles day Functions Drift 1 s day Power reserve 6 hours no battery required Connectable ran dom generator 0 30 minutes Astro function Astro time shift 2 hours Standard blind movement time 2 minutes Display elements 5 LED LCD display Operating elements Menu push button Manual push button OK push button arrow push button UP arrow push button DOWN Connection module interface ...

Reviews: