background image

Connect the GREEN wire to the grounding screw in the box. If 

a plastic box, connect to ground as supplied.
Make sure all twist connectors are tight.

If a 3-Way Switch Setup:

NOTE: The distance between 
switch timer and remote switch 
must not exceed 100 feet.

 Locate the COMMON 

wire connected to first old 

switch. It might be attached 

to a different colored screw, 

or find markings on old switch.
Connect BLACK wire from switch timer to COMMON wire, 

using a twist connector.
Connect the other two wires from the old switch to the Blue 

and RED wires from the switch timer.
Connect the GREEN wire to the grounding screw in the box. If 

a plastic box, connect to ground as supplied.
Using diagram #1 below. Identify and remove wire “C” from 

the “Common” terminal of your existing remote switch. 

Using diagram # 2 below, remove and reconnect wires “B”  

and “C” to the “Common” terminal of your remote switch, 

using the supplied piece of jumper wire, if necessary. Follow 

diagram # 3 below, if using a new single-pole remote switch. 

NOTE: For new construction or to replace a dimmer switch, 
a lighted switch, or a 3-way switch without screw terminals, 
a single-pole switch can be used at the remote location, as 
shown.
NOTE: If the building’s wiring colors don’t allow you to tell 
wire “A” from “B,” just pick one of the two wires and connect 
as if it is wire “B.” After the installation is complete, if the con-
trolled light or device will not turn on properly, simply reverse 
wires “A” and “B.” See Steps 

J

 and 

K

 for how to check.

Tuck wires into the timer wall box leaving room for the timer.
Using screws provided, mount the switch timer into the wall 

box, then install the wall plate.
Install the remote 3-way switch in its box and install wall 

plate. Turn the power back on at the service panel.
Make sure the switch timer displays “MAN” mode. Do the fol-

lowing test with the remote switch in each of its 2 positions:  

Press the 

ON/OFF

 button on the switch timer several times. 

Each time that you push the 

ON/OFF

 button, the switch timer 

should “click” and the controlled light or device (the “load”) 

should turn on or off. If so, proceed to Step 

K

.

If the timer clicks but the load does not operate, re-check 

your wiring and make sure the load is functional.

c.

d.

a.

b.

c.

d.

e.

f.

g.
h.

i.

j.

-

Self-Adjusting Wall Switch Timer

Turn off power at the service panel by REMOVING FUSE or 

TURNING THE CIRCUIT BREAKER OFF.
Remove the existing wall switch.
Trim building wires to 7/16” as shown.

If a Single Switch Setup:

Connect one of the two wires 

from the wall to the black wire 

from the switch timer, using 

the twist connectors provided. 
Connect the other wire from 

the wall to the blue wire from 

the switch timer, using the 

twist connectors provided.

NOTE: The RED wire is not used in single-switch installations. 
Cap with a twist connector.

1.

2.
3.

a.

b.

Resistive (

heater

) 15 Amp, 120-277 VAC

Tungsten (

incandescent

) 15 Amp @ 120 VAC, 6 Amp @ 208-277 VAC

Ballast (

fluorescent

) 8 Amp @ 120 VAC, 4 Amp @ 208-277 VAC

Motors 1 H.P. @ 120 VAC, 2 H.P. @ 240 VAC
DC Loads 4 Amp @ 12 VDC, 2 Amp @ 28 VDC

Installation and User Instructions

MODEL ST01 Series

2 – Install the Switch Timer

Ratings

Before installing the switch timer into the wall, make sure the 

supplied battery is installed and working. 

Open the access door to reveal the battery tray, located below 

the ON/OFF keypad.
If there is a pull tab at the battery tray, remove the tab to con-

nect the installed battery. Make sure battery tray is pushed 

fully into place. Proceed to Step 6.
If the battery was supplied loose, use a flat screwdriver to pry 

loose the battery tray.
Place the supplied “CR2” battery into the tray, observing 

+

 

and 

 markings on tray.

Replace the battery tray into the switch timer.
The display will initialize itself then flash “12:00 AM” in 

MANual mode.
Press the 

ON/OFF

 button. The switch timer should “click.”

NOTE: If display doesn’t flash “12:00 am”, the battery may be 
dead. Replace the battery before installing the switch timer.

1.

2.

3.

4.

5.
6.

7.

1 – Before Installing Switch Timer, Install and Check Battery

BLACK WIRE

BLUE WIRE

RED WIRE

(capped, not connected)

RED WIRE

BLUE WIRE

BLACK WIRE

WIRE FROM

“COMMON” OF

OLD SWITCH

7/16”

DIAGRAM 1:

TYPICAL

EXISTING

2-SWITCH

SETUP

LOAD

NEUTRAL

3-WAY 

MAIN SWITCH

WIRE “A”

“COMMON” TERMINAL

LINE

3-WAY 

REMOTE SWITCH

WIRE “B”

WIRE “C”

DIAGRAM 2:

2-SWITCH SETUP,

TIMER INSTALL

RE-USING EXISTING

REMOTE 3-WAY SWITCH

LOAD

NEUTRAL

WIRE “A”

“COMMON” TERMINAL

LINE

3-WAY 

REMOTE SWITCH

WIRE “B”

NOT USED

BLACK

TIMER

BLUE

RED

WIRE “C”

JUMPER

DIAGRAM 3:

2-SWITCH SETUP,

TIMER INSTALL USING 

NEW SINGLE-POLE 

REMOTE SWITCH

LOAD

NEUTRAL

WIRE “A”

LINE

SINGLE-POLE

REMOTE SWITCH

WIRE “B”

BLACK

TIMER

BLUE

RED

WIRE “C”

JUMPER

158ST13133

Observed Problem

Possible Cause

What to Do

Switch timer does not switch ON/OFF but 

display looks normal.

Switch timer is not set in AUTO, RANDom, or 

MANual mode.

Press 

MODE

 to select the operational mode you 

want to use.

Switch timer won’t enter AUTO or  

RANDom mode when you press 

MODE

.

The time of day or timer settings have not 

been set.

Make sure the time of day and at least one sched-

uled activity have been set.

Switch timer switches at incorrect times 

or skips some of the programmed times.

Programmed schedule(s) are incorrect.

Press 

ON/OFF 

to review the settings and revise 

them as necessary. See instructions at the left.

Switch timer is in RANDom mode, which var-

ies switching times up to ±20 minutes (to give 

your home a “lived-in” look).

If you don’t want to keep the switch timer in 

RANDom mode, press 

MODE

 to change to AUTO 

mode.

The Astronomic and Specific switching times 

are in conflict. For example, you’ve set ON to 

DUSK and OFF at 8 pm, and due to seasonal 

changes, DUSK has advanced to 8:30 pm. 

NOTE: Your switch timer automatically skips 
any conflicting ON event as summer ap-
proaches to prevent unwanted operation of 
lights or other controlled devices. See “What 
to Do” if you want to identify and remove 
conflicting settings.

Complete the steps for setting the Time and 

Date, then temporarily change the date to 

June 21st.
Review the DAWN and DUSK settings by 

pushing the 

ON/OFF

 button. 

Make sure the specific ON or OFF time set-

tings won’t interfere with these DAWN and 

DUSK times. Make changes as necessary.
When finished, change the Date setting back 

to today’s date. 

1.

2.

3.

4.

The lights or controlled devices don’t 

match the programmed ON/OFF status 

immediately after setting the time or 

programming a schedule.

Switch timer does not “catch up” automati-

cally to the programmed load state. The status 

of the switch timer will remain as is until it 

comes to the next programmed ON/OFF time.

After entering your schedules or the time, then 

returning to the AUTO mode, push the 

ON/OFF

 but-

ton to change the load state if necessary.

Load only operates when the remote 

(3-way) switch is in one position, or the 

switch timer ignores the remote switch.

The remote switch is wired incorrectly.

Recheck the wiring, especially for the jumper, 

according to “If a 3-way Switch Timer” and “If a 

Multiple Switch Timer Setup.”

The switch timer ignores a 3-way remote 

switch even though it is wired correctly.

There is an excessive length of wire (more 

than 100 feet), or there is buried wire to the 

switch.

Eliminate the condition: either replace the buried 

cable, do without the remote switch, or contact 

Intermatic Customer Service for more options.

The remote switch is not functioning properly 

or worn out.

Replace the remote switch.

The load turns off immediately after being 

turned on.

The remote switch or switch timer is wired 

wrong.
There is an excessive length of wire 

(greater than 100 feet)
There is buried wire to the remote switch.
The switch timer is not functioning properly.


If the problem persists with the switch timer’s red 

wire disconnected or with a remote switch tempo-

rarily connected right at the switch timer, replace 

the non-functioning switch timer. Otherwise, try 

the above suggestions.

The battery tray is difficult to replace.

Battery is not seated in the tray.
The tray is misaligned.
The contact tabs of the tray are bent.



Seat the battery in the tray, then reinstall.

The switch timer operation is sluggish or 

not switching ON/OFF at all.

Though the “BATT” message is not being 

displayed, the battery is getting weak. 

Replace the battery. 

To test the battery, press the 

ON/OFF

 button. The timer should “click.”

Timer shows ON but the light or other 

controlled device is OFF.

The light or controlled device itself may be 

switched OFF.

Make sure the light or controlled device is 

switched ON and plugged in.

Troubleshooting Guide

LIMITED ONE-YEAR WARRANTY

If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is 

extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; 

(b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed 

lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, 

removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL 

DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE 

WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF 

THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO 

YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage prepaid to the authorized 

service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7000 http://www.intermatic.com Please be sure to wrap 

the product securely to avoid shipping damage.

INTERMATIC INCORPORATED 

SPRING GROVE, ILLINOIS 60081-9698

Electrical shock hazard. Risk of injury or death. Remove electrical power 

at service panel before installing.
Risk of fire or burns from used battery. Do not recharge, disassemble, heat 

above 100˚ C, crush, or incinerate the lithium battery. Keep battery out of 

reach of children. Replace only with Panasonic type CR2 or equivalent 

CR2 battery approved by Underwriters Laboratories (UL). Use of a differ-

ent battery type may present a risk of fire or explosion upon disposal of 

battery.
Risk of fire. Do not use timer to control devices that could have danger-

ous consequences due to inaccurate timing, such as sun lamps, sauna, 

heaters, crock pots, etc.

          WARNING

Follow local electrical codes during installation.
Risk of timer damage due to leakage if weak battery is not replaced promptly.
Dispose of used battery promptly per local regulations.



NOTICE