background image

V5

75

5-

58

1-

02

 0

1/1

5

2

Front:

*Can only be selected as alternative in combination with 

a central unit insert (from version 1.5).

Rear:

A

Module interface

Connections, displays and operating 

elements

A

Display

B

Menu button

C

Manual push-button

D

OK button

E

UP arrow button 

• Push-button function (factory setting): Raising/

switching on

• Scene function*: Scene 1

F

DOWN arrow button 

• Push-button function (factory setting): Lower-

ing/switching off

• Scene function*: Scene 2

G

LEDs

A

B

C

E

D

F

G

A

Display elements

|

The displayed symbols depend on the inserts 

used and the sensors connected via PlusLink.

Individual display elements

You will see the following symbols on the display:

Standard display

Example of the standard display during operation:

A

Insert (see function overview)

B

Frame

C

Display timer module

Time, value and information display

Display of the weekdays

1 = Monday  to  7 = Sunday
Automatic mode

Astro function

Random function

• Status display with switched 

load: Light on or raising the blind

• Switching times for raising/

switching on

• Status display with switched 

load: Lowering the blind

• Switching times for lowering/

switching off

Setting the time

Setting the day, month and year

Switching time 2

Sun protection function activated,

Setting the brightness threshold
Wind alarm is executed,

Setting the behaviour for wind 

alarm
Switching between summer and 

winter time
DCF timer is evaluated

Mounting the module

B

C

A

Initialising the module

After plugging the module onto the insert for the first 

time, information on the module type and module version 

are displayed for one second each. A standard display 

follows this, either with a flashing clock symbol or a DCF 

symbol.

Module type display: Display timer module

Standard display with flashing clock symbol

Set time and date (see Section "Setting module: Basic 

menu settings").

Standard display with DCF symbol

|

The DCF timer is detected 5 minutes after con-

necting to the mains supply.

Time and date were received via a DCF timer.

Error message after changing over the module 

If the module is plugged onto an insert that differs in func-

tionality from the previous one, the error message "FAIL" 

appears and all LEDs flash red.
For initialisation, reset the module to the default settings.

|

When you do a reset to the default settings, previ-

ously saved settings are lost! The set time and 

date are not reset.

1

Press the push-buttons   and   simultaneously for 

10 seconds.

The standard display appears after resetting.

10 s

Menu

OK

Man

Summary of Contents for MEG5755-03 series

Page 1: ...witchover Individually adjustable blind movement time Adjustable brightness threshold for sun protection function Adjustable response for wind alarm Adjustable display brightness Automatic deactivation of display lighting can be se lected from version 1 5 Power reserve of at least 6 hours in the event of a pow er failure Reset restore default settings Table of Content Getting to know the display t...

Page 2: ...g the time Setting the day month and year Switching time 2 Sun protection function activated Setting the brightness threshold Wind alarm is executed Setting the behaviour for wind alarm Switching between summer and winter time DCF timer is evaluated Mounting the module B C A Initialising the module After plugging the module onto the insert for the first time information on the module type and modu...

Page 3: ...ion for sun protection function Set response for wind alarm Set display brightness Set automatic deactivation of display lighting The following push buttons are used to operate the menu With a long press of Menu the menu for setting the time and switching time appears after 2 s To open the advanced menu hold the Menu push button down If you do not press any push button in the menu for more than 2 ...

Page 4: ...sh button or 7 Confirm setting with OK The time display flashes 8 Set switching time with or push button 9 Confirm setting with OK The operating mode display flashes 0 Select operating mode with or push button and confirm with OK The time display flashes Set second switching time with or push but ton Confirm setting with OK If you press the Man push button a switching time set previously appears T...

Page 5: ...1 display appears 3 Confirm setting with OK The no display appears 4 Select save option yes with push button or 5 Confirm setting with OK Light scene All lamps are switched off briefly and then back on again to indicate that the saving procedure has been successful Then the lamps adopt the saved brightness value Blind scene The blinds are lowered and raised by one step to indicate that the saving ...

Page 6: ...astro function separately for each switching time see Set switching times If the activated astro function has calculated that it will still be dark outside at the set switching time e g Raise blind at 6 30 a m it will not raise the blind until the sun rises Likewise the blind will be lowered at sunset if the acti vated astro function has calculated that it will be dark be fore the set switching ti...

Page 7: ...damage caused by strong wind you can set a blind behaviour for wind alarm As soon as the wind speed set on the wind sensor has been steadily exceeded for a period of at least 15 sec onds the blind reacts according to the set behaviour see Setting the behaviour for wind alarm There are three possible settings Blind is lowered in the event of wind alarm standard setting Blind is raised in the event ...

Page 8: ...L2 PL1 0 5 s 0 5 s 0 5 s 0 5 s Menu OK Man 0 5 s Menu OK Man Central unit insert or side controller Plus 1 gang 2 gang switching dimming controlling blinds and retrieving scenes Mechanical push button double push button Sensor interface sensors FAIL flashes on the display all LEDs flash red Module was plugged onto an insert that differs in func tionality from the previous one Reset module to defau...

Page 9: ...per PL line 2 switching cycles day Functions Drift 1 s day Power reserve 6 hours no battery required Connectable ran dom generator 0 30 minutes Astro function Astro time shift 2 hours Standard blind movement time 2 minutes Display elements 5 LED LCD display Operating elements Menu push button Manual push button OK push button arrow push button UP arrow push button DOWN Connection module interface ...