background image

- 1 -

AS-221T

Staircase lighting timer 

with switch-off indication

Staircase lighting timer (time switch) is used to keep the lighting 

on in corridors, staircases or other places for a certain period of 

time, after which the lighting will be switched off automatically.

When activated by momentary (bell) switch the staircase lighting 

timer keeps the lighting switched on for the time set by the po-

tentiometer (from 0.5 to 10 minutes), after which the brightness 

of the lighting system is reduced by half for about 30 seconds. 

Only after this time will the lighting be completely switched off 

(sudden darkness is avoided, there is time for safe access to the 

switch). During the reduced brightness the subsequent signal 

from the switch will switch the lighting back on to full brightness.

Purpose

Functioning

F&F Filipowski sp. j.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: [email protected]

Do not dispose of this device in the trash along with other waste!  

According to the 

Law on Waste, electro coming from households free of charge and can give any amo-

unt to up to that end point of collec� on, as well as to store the occasion of the pur-

chase of new equipment (in accordance with the principle of old-for-new, regardless 

of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Summary of Contents for AS-221T

Page 1: ...dden darkness is avoided there is time for safe access to the switch During the reduced brightness the subsequent signal from the switch will switch the lighting back on to full brightness Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Do not dispose of this device in the trash a...

Page 2: ...connect the power supply 2 Mount the device on a rail in the distribution box 3 Connect to the circuit according to the diagram 4 Set the operating time using a flathead screwdriver Mounting Connection diagram ...

Page 3: ...AS 221T can work with backlit buttons The device does not work with lamps not adapted to phase control such as LED lamps fluorescent lamps compact fluorescent lamps or other lamps with electro nic starter ...

Page 4: ...ure 25 50 C dimensions 2 modules 35 mm mounting on TH 35 rail ingress protection IP20 tungsten halogen fluorescent energy saving LED 1250W 900W 600W 300W 150W The above data are indicative and will heavily depend on the design of a specific receiver that is especially important for LED bulbs energy saving lamps electronic transformers and pulse power supply units switching frequency and operating ...

Page 5: ... j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the references to the standards in relation to which conformity is declared can be found at www fif com pl on the product page Warranty CE declaration E210203 ...

Page 6: ......

Reviews: