Lubrication & Maintenance
Breather
CAUTION
COVER THE BREATHER WHEN STEAM CLEANING THE
HOUSING. IF THE BREATHER IS NOT COVERED, WATER CAN
ENTER THE HOUSING AND CONTAMINATE THE OIL.
The breather releases pressure that builds up inside the transfer case
during vehicle operation. Figure 10.1, Figure 10.2, and Figure 10.3.
Figure 10.1
MTC-4208XL & MTC-4210XL REAR COVER
4007127a
BREATHER
Figure 10.2
MTC-4208XLEV & MTC-4210XLEV FRONT COVER
4011824a
BREATHER
Figure 10.3
MTC-4213X REAR COVER
4004233g
REAR
OUTPUT
POSITION
BREATHER
Seals
CAUTION
ALWAYS USE THE CORRECT TOOLS AND PROCEDURES
WHEN REPLACING A SEAL. A SEAL NOT CORRECTLY
INSTALLED CAN LEAK. DAMAGE TO COMPONENTS CAN
RESULT.
Seals keep lubricant in and dirt out of a component. When they are
worn or damaged, seals leak and produce low lubricant levels which
may damage components.
Always replace unitized seals after yokes have been removed. MLS
seals may be reused if they are not damaged or leaking.
Meritor has released the multiple-lip seal (MLS) for use in the INPUT
POSITION ONLY on the MTC-4208, MTC-4210, and MTC-4213 trans-
fer cases. The multiple-lip seal is compatible with the current input
shaft seal and can be used in service. Refer to Figure 10.4 for the
INPUT position and front OUTPUT position. Refer to Figure 10.1 for the
MTC-4208 and MTC-4210 rear OUTPUT position. Refer to Figure 10.3
for the MTC-4213 rear OUTPUT position.
Figure 10.4
MTC-4208X/XP, MTC-4210X/XP, & MTC-4213X
4006338f
OIL COOLER READY
INLET
TUBE
FITTINGS
DRAIN
PLUG
FILL
PLUG
FRONT VIEW
FRONT INPUT
YOKE
FRONT
OUTPUT
YOKE