2 - COMPONENTS AND CONTROLS (PIC. 1)
1) Handle for transport
2) Fuel cap
3) Fuel tank
4) Fuel shutoff
5) Starting handle and cable
6) Engine switch
7) Choke lever
8) Air filter
9) AC Socket (alternating current)
10) Generator
11) Muffler
12) Engine
13) Spark plug
14) DC Socket (direct current) - 12 V
3 - PRE-OPERATION PREPARE
1. To prevent get an electric shock, when operating the machine
link with earth (pic. 2)
2. Prepare the 2% lead-free petrol and oil in a container.
Use the filler cap of the tank (pic. 3/b) as an oil measure.
WARNING:
observe the quantities specified by the table.
3. Fuel tank capacity:
4,2
liters.
4. Pour the mixture into the tank and close the cap well.
WARNING:
never remove the filter from the tank when you pour
the mixture.
WARNING:
Do not refill tank while engine is running or hot.
Close the fuel cock before refueling with fuel.
Be careful not to allow dust, dirt, water or other foreign
objects into the fuel.
Wipe off spilt fuel thoroughly before starting engine.
.
4 - STARTING THE ENGINE
Before starting, do not connect electric equipments. (pic. 4/a)
1. Shake fuel tank before starting engine.
2. Turn fuel cock lever «ON». (pic. 4/b)
3. Turn choke lever to
(1) (pic. 5/a)
4. Turn engine switch to «ON». (pic. 5/b)
5. Pull slowly on recoil starter until engaged, then pull it briskly
(pic. 6/a)
CAUTION:
Do not allow the starter grip to snap back against
the engine. Return it gently to prevent damage to the starter
or housing.
6. When the motor is on, arrange the air lever in the middle and
let the engine warm up for a couple of minutes.
Return choke lever back. (pic. 6/b)
ATTENTION:
The motor might fail to start at once at the first start up.
Repeat the operation until it starts. When the motor is warm, you
might not be required to pull the air lever.
NEVER power on the generator in a closed environment since
exhaust gases produce carbon monoxide, a gas causing loss
of consciousness and death.
5 - APPLICATIONS CHART
NPEGG780 - AC Power
Power Factor
50 Hz
~ 650 W
1
60 Hz
~ 800 W
50 Hz
~ 480 W
0.7-0.8
60 Hz
~ 600 W
50 Hz
~ 570 W
0.7-0.95
60 Hz
~ 700 W
NPEGG780 - When charging the batteries
12V / 8.3 A
Maximum
chargeable capacity:
40 A.h. (Ampere/hour)
6 - CONNECTION (PIC. 8/B)
1. Ensure that electrical equipment is switched off before
connecting to the generator.
2. Connect the plug of the electrical equipment into the
appropriate socket.
12V CIRCUIT PROTECTOR (PIC. 9)
The 12V Circuit Protector turns on automatically when the load
exceeds the maximum rated output.
Press the button to reset protector, reduce output load if AC
protector turns off.
(1) - ON
(2) - OFF
7 - STOPPING THE ENGINE
1. Before stopping, turn off and disconnect from generator the
electric equipments. (pic. 4/a)
2. Turn engine switch to «STOP». (pic. 7/a)
3. Turn fuel cock lever to «OFF». (pic. 7/b)
LEAD-FREE
PETROL
OIL
WARNING!
DO NOT USE THE GENERATOR TO SUPPLY POWER
TO ELECTRONIC EQUIPMENT.