Log Event Codes (Cont.)
LCD
Starburst
LED
Description
ENTRY 01-38
ENTRY 01-38
En.01-38
Entry timer started by circuit (01-38).
ENTRY ALARM 01-38
EN.ALM 01-38
EA.01-38
Entry timed-out alarm from circuit (01-38).
FACTORY RESTART
FACT. RST
Fr
System “Factory Restarted”.
FIRE ALARM 01-38
FIRE 01-38
FA.01-38
Fire alarm circuit activated.
FIRST KNOCK 01-38
FIRST 01-38
Fn.01-38
The first activation of a Double Knock circuit.
FUSE BLOWN 01
FUSE 01
FB.01
Control Panel 12V Auxiliary Fuse blown.
KEY POINT 01-38
KEY.SW 01-38
So.01-38
Key point operation from circuit (01-38).
LINE FAULT
LINE FLT
LF
Telephone line fault detected.
LINE RESTORED
LINE OK
Lr
Telephone line fault restored.
MODEM LOCK-OUT
LOCK-OUT
LO
Modem failed to communicate.
NO EVENT
NO EVENT
No log event.
OMITS REMOVED
OMIT REM
Or
Previously omitted circuits reinstated.
ON-SITE RESTART
SITE. RST
Sr
System “On-Site” restart.
PA ALARM 01-38
PA.ALM 01-38
PA.01-38
Panic Alarm circuit activated.
PA CODE 00-15
PANIC 00-15
PC.00-15
Panic Alarm passcode entered (00 = Keypad PA).
PANEL LID TAMPER
LID TAMP
LT
Control panel lid removed.
PART SET A/B/C
P.SET A/B/C
PS.A/B/C
System Part-Set using one of the A, B, or C buttons.
PASSCODE 00-15
USER 00-15
Ur.00-15
User passcode entered. (00-15).
REM REMOVED 01-04
R. REM 01-04
rr.01-04
Remote Keypad removed from system.
REM SERVICE CALL
R.S. CALL
SC
Remote service call via “Lineload” software and PC.
REM TAMPER 01-04
R. TMP 01-04
rT.01-04
Remote Keypad cover removed.
REMOTE ADDED 01-04
R. ADD 01-04
RA.01-04
Remote Keypad added to the system.
REMOTE RESET
REM RST
rc
System reset by “Remote Reset” passcode.
SERVICE CALL END
R.S. END
SE
Remote service call finished.
SERVICE REQUIRED
SERVICE
rS
Service required
SET FAIL
SET FAIL
SF
System failed to Set.
SYSTEM OPEN
SYS OPEN
OP
System fully unset.
SYSTEM RE-ARMED
RE-ARMED
rA
System re-armed all healthy circuits.
SYSTEM SET
FULL SET
FS
System fully set.
TAMPER 00
TAMP'R 00
TA.00
Short circuit on ID loop.
TAMPER 01-38
TAMP'R 01-38
TA.01-38
Tamper alarm from circuit.
TEST CCTS OFF
TEST OFF
To
All circuits taken off “Test”
TEST FAIL 01-38
T. FAIL 01-38
TF.01-38
Circuit failed during “Test”.
TIME CHANGED
TIME CHG
Tc
System time changed
WALK TEST
WALK TST
cT
System “Walk Test” selected.
36