Setup New Users
The TS690 and TS690ID allows up to 15 users to operate the alarm system, each user is
assigned a user type and a passcode. User 01 is the master user which has a default
setting of 5678.
User Types
The following user types are available:
1 - Master
This user type can full set, part set and unset the system. A master user
also has access to all user menus and options providing the alarm
company has programmed the master user for full access. If the
master user has been programmed for limited access the master
user cannot access user menu 2 option 6 (Alter shunt group) and 8
(Configure Part Sets).
2 - Standard
This user type can full set, part set and unset the system. A standard
user also has access to all the options in user menu 1.
3 - Holiday
This user type can full set, part set and unset the system. A holiday user
also has access to all the options in user menu 1. However, When the
system is next unset by a master user, the holiday passcode is
automatically deleted from the system.
4 - Set Only
This user type operates in the same way as a standard user, except
that it only allows setting and part setting of the system.
5 - Reset Only
This user type allows unset alarms such as 24hr, fire, auxiliary to be
silenced and reset. The user type also has access to user menu 1
options 1 to 7.
6 - Duress
This user type operates in the same way as a standard user, but when
the passcode is used a silent “Panic Alarm” is transmitted to the alarm
receiving centre.
If enabled by your alarm company all users can generate a “Duress”
alarm by entering their passcode with the first two digits reversed
(e.g. for a passcode of 2580 enter 5280 to generate a “Duress”
alarm).
7 - PA Code
This user type does not have access to any user menus nor can it be
used to set and unset the system. When this user code is entered a
“Panic Alarm”' is transmitted to the alarm receiving centre and the
external sounder(s) and strobe light(s) are also activated.
8 - Shunt
This user type does not have access to any user menus nor can it be
used to set and unset the system. When this user code is entered it will
isolate a predefined group of detection circuits. When the code is
re-entered it will reinstate the group.
This user type is displayed as “Access” on the starburst remote
keypad.
28