Walk Test
This option allows you to test the function of individual detection circuits without causing an
alarm. As each circuit is activated the circuit number and status are displayed and the
internal sounders generate a two tone “Chime” sound. Once the test has been completed
the tested circuits can be reviewed in numerical order.
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
SYSTEM OPEN
17:30 01 JAN
Walk Test
Press ESC to end
Office Window
CCT 14 Active
Office Door
CCT 12 Active
Tested CCTs were
Press ESC to end
1 -
OPEN
OPEN
NONE
14-A
12-A
12-H
2
2
2
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
Office Door
CCT 14 Healthy
14-H
Office Door
CCT 12 Healthy
User menu 1
Select Option :
1
? ? ? ?
ENT
+
? ? ? ?
ENT
+
? ? ? ?
ENT
+
LCD Remote
Starburst Remote
LED Remote
1.
From the unset (open) mode enter your passcode and press
[ENT]
to select user
menu 1.
2.
Whilst user menu 1 is selected. Press
[2]
to select the walk test option.
3.
Activate detection circuits in turn by opening doors with alarm contacts and walking
in front of movement detectors.
4.
When the test has been completed, press the
[ESC]
key. The display will now
automatically scroll through the circuits that were tested in numerical order. The
current status of the circuit is also displayed. The
[ENT]
key can be used to scroll
through the tested circuits more quickly, if desired.
15